To determine whether fibrin sealant injected into the tract created by liver biopsy can be used to decrease postprocedural bleeding. An innovative delivery system was used to deploy the fibrin sealant.
Fibrin sealant is a hemostatic agent consisting of a suspension of fibrinogen and thrombin. A delivery system was devised whereby fibrin sealant could be injected into the tract created by liver biopsy. Thirty swine were randomized into three groups: control (n = 10), heparin (n = 10), and warfarin (n = 10). Each swine underwent laparotomy and was randomized to undergo three to five open liver biopsies with either a 14-gauge cutting needle in conjunction with the fibrin sealant device or a standard 14-gauge cutting needle alone. Forty-seven biopsy procedures were performed with the device; 64 biopsy procedures were performed without the device. Immediate blood loss per biopsy (mL) was estimated based on the size of the blood stain on a sponge. Specimens were assessed for sample size.
Immediate blood loss with and without the device, respectively, was: control, 0.1 mL, 5.4 mL; heparin, 0 mL, 7 mL; warfarin, 0.1 mL, 9.3 mL. These differences were significant (P < .01) for each group of swine. In 43 of 47 biopsies (91%), the device functioned without difficulty. There was no difference in sample size when the device was used.
The fibrin sealant device is effective in reducing bleeding after open liver biopsy in anticoagulated and nonanticoagulated swine. The promising results suggest that a trial of percutaneous liver biopsy in swine should be considered.
确定注入肝活检所造成通道内的纤维蛋白封闭剂是否可用于减少术后出血。采用了一种创新的输送系统来部署纤维蛋白封闭剂。
纤维蛋白封闭剂是一种由纤维蛋白原和凝血酶悬浮液组成的止血剂。设计了一种输送系统,通过该系统可将纤维蛋白封闭剂注入肝活检所造成的通道内。30头猪被随机分为三组:对照组(n = 10)、肝素组(n = 10)和华法林组(n = 10)。每头猪均接受剖腹手术,并随机接受三至五次开放性肝活检,使用14号切割针并结合纤维蛋白封闭剂装置,或仅使用标准的14号切割针。使用该装置进行了47次活检操作;未使用该装置进行了64次活检操作。根据海绵上血迹的大小估计每次活检的即时失血量(毫升)。对标本进行样本量评估。
使用和未使用该装置时的即时失血量分别为:对照组,0.1毫升,5.4毫升;肝素组,0毫升,7毫升;华法林组,0.1毫升,9.3毫升。每组猪的这些差异均具有统计学意义(P < 0.01)。在47次活检中的43次(91%)中,该装置运行顺利。使用该装置时样本量没有差异。
纤维蛋白封闭剂装置在减少抗凝和未抗凝猪开放性肝活检后的出血方面有效。这些有前景的结果表明应考虑在猪身上进行经皮肝活检试验。