Suppr超能文献

通过试验性团注注射预测和控制时间依赖性主动脉强化的准确性。

Accuracy of predicting and controlling time-dependent aortic enhancement from a test bolus injection.

作者信息

Hittmair K, Fleischmann D

机构信息

Department of Radiology, University of Vienna, Vienna, Austria.

出版信息

J Comput Assist Tomogr. 2001 Mar-Apr;25(2):287-94. doi: 10.1097/00004728-200103000-00024.

Abstract

PURPOSE

The purpose of this work was to determine the accuracy of predicting arterial enhancement from peripheral versus central venous test bolus injections at CT angiography (CTA).

METHOD

In 40 patients with abdominal aortic aneurysms, aortoiliac enhancement profiles were predicted by mathematical deconvolution of the time-attenuation response to a 16 ml test bolus injection. Injection sites were either a cubital vein (n = 20) or a central venous injection site (n = 20). The accuracy of predicting enhancement was quantified as the "off-predicted deviation" (calculated as mean squared differences between observed minus predicted enhancement values) in all patients.

RESULTS

Off-predicted deviation was significantly smaller in the central venous injection group (17 +/- 6 HU) than the peripheral injection group (33 +/- 18 HU) (p < 0.001).

CONCLUSION

Arterial enhancement at CTA can be mathematically predicted and controlled more accurately if a central venous injection site is used. Automated saline flushing of the veins might improve the accuracy of the mathematical model for peripheral injections.

摘要

目的

本研究旨在确定在CT血管造影(CTA)中,通过外周静脉与中心静脉团注试验来预测动脉强化的准确性。

方法

对40例腹主动脉瘤患者,通过对16ml团注试验的时间-衰减反应进行数学反卷积来预测腹主动脉-髂动脉强化曲线。注射部位为肘静脉(n = 20)或中心静脉注射部位(n = 20)。将所有患者中预测强化的准确性量化为“预测偏差”(计算为观察到的强化值减去预测强化值之间的均方差异)。

结果

中心静脉注射组的预测偏差(17±6HU)显著小于外周注射组(33±18HU)(p < 0.001)。

结论

如果使用中心静脉注射部位,CTA时的动脉强化可以通过数学方法更准确地预测和控制。静脉自动盐水冲洗可能会提高外周注射数学模型的准确性。