软性胃肠道内窥镜再处理用高水平消毒剂和灭菌剂的使用指南。

Guideline for the use of high-level disinfectants and sterilants for reprocessing of flexible gastrointestinal endoscopes.

出版信息

Gastroenterol Nurs. 2000 Jul-Aug;23(4):180-7. doi: 10.1097/00001610-200007000-00008.

Abstract

Glutaraldehyde, 0.2% peracetic acid, 7.5% hydrogen peroxide, 0.08% peracetic acid/1% hydrogen peroxide, and 0.55% ortho-phthalaldehyde are cleared by the FDA for reprocessing flexible gastrointestinal endoscopes. Each product has advantages and disadvantages. All require adherence to published reprocessing protocols in order to maintain the integrity of equipment while providing the public with endoscopic instruments that are safe and effective. All chemicals must be handled with respect. Selection of a product must be weighed against the needs of a particular setting, taking into consideration factors such as compatibility, toxicity, environmental controls and cost.

摘要

戊二醛、0.2%过氧乙酸、7.5%过氧化氢、0.08%过氧乙酸/1%过氧化氢和0.55%邻苯二甲醛已获得美国食品药品监督管理局(FDA)批准,可用于软性消化内镜的再处理。每种产品都有优缺点。所有产品都需要遵守已公布的再处理规程,以保持设备的完整性,同时为公众提供安全有效的内镜器械。所有化学物质都必须谨慎处理。选择产品时,必须根据特定环境的需求进行权衡,同时考虑兼容性、毒性、环境控制和成本等因素。