Kobayashi S, Matsui O, Gabata T
Department of Radiology, Kanazawa University School of Medicine, 13-1, Takara-machi, Kanazawa, 920-8641, Japan.
Br J Radiol. 2001 Mar;74(879):273-6. doi: 10.1259/bjr.74.879.740273.
A case of a pseudolesion in segment IV of the liver, adjacent to the falciform ligament, was observed on conventional CT and CT during arterial portography. The pseudolesion was caused by drainage of the paraumbilical vein. Power Doppler ultrasound was helpful in recognizing this pseudolesion by depicting that the paraumbilical vein was connected to vessels in this area. Although the direction of flow could not be determined, power Doppler ultrasound is a useful method for confirming non-invasively the aetiology of pseudolesions in this area.
在常规CT及动脉门静脉造影CT上观察到1例肝脏IV段假病灶,该假病灶毗邻镰状韧带。该假病灶由脐旁静脉引流所致。能量多普勒超声通过显示脐旁静脉与该区域血管相连,有助于识别此假病灶。尽管血流方向无法确定,但能量多普勒超声是一种非侵入性确认该区域假病灶病因的有用方法。