Suppr超能文献

股骨部件偏移对全髋关节置换术中聚乙烯磨损的影响。

Effect of femoral component offset on polyethylene wear in total hip arthroplasty.

作者信息

Sakalkale D P, Sharkey P F, Eng K, Hozack W J, Rothman R H

机构信息

Department of Orthopaedics, The Rothman Institute, Thomas Jefferson University, Philadelphia, PA 19107, USA.

出版信息

Clin Orthop Relat Res. 2001 Jul(388):125-34. doi: 10.1097/00003086-200107000-00019.

Abstract

Seventeen staged, bilateral total hip arthroplasties performed in 17 patients were reviewed to compare side-to-side polyethylene wear. Implants used on both sides were similar except for implant offset: one hip in each patient was replaced using a femoral component having a standard implant offset, whereas the other side had a lateral offset implant. The mean followup was 5.70 years (range, 2-10.2 years) on the side with a standard femoral implant and 5.67 years (range, 2-9.7 years) on the side with a lateralized femoral component. The only statistically different parameter between the sides was the femoral component offset. All other parameters affecting polyethylene wear, such as period of followup, head size, head type, cup size, cup inclination, medialization of cup, and patient-related factors were similar on both sides. On the side with a standard femoral component, the mean actual prosthetic offset (determined by manufacturer's specifications) was 35.2 mm and the radiologic offset was 31.5 mm. On the side with a lateralized femoral component, the actual prosthetic offset was 42.5 mm and the radiologic offset was 40.1 mm. The difference in offsets between the sides was statistically significant. The mean preoperative offset of the femur was 38.8 mm. Regression analysis revealed that only femoral component offset and cup size correlated significantly with linear wear rate. On the side with a standard femoral component, the linear wear rate was 0.21 mm per year, whereas on the side with a lateralized femoral component, the linear wear rate was 0.10 mm per year. The differences in the linear wear rates were significant. Lateralization of the femoral component in this series more closely restored preoperative hip biomechanics and significantly decreased polyethylene wear.

摘要

回顾了17例患者接受的17次分期双侧全髋关节置换术,以比较双侧聚乙烯磨损情况。除了假体偏移外,两侧使用的植入物相似:每位患者的一侧髋关节使用具有标准假体偏移的股骨组件进行置换,而另一侧使用外侧偏移假体。使用标准股骨假体一侧的平均随访时间为5.70年(范围2 - 10.2年),使用外侧化股骨组件一侧的平均随访时间为5.67年(范围2 - 9.7年)。两侧之间唯一有统计学差异的参数是股骨组件偏移。影响聚乙烯磨损的所有其他参数,如随访时间、股骨头大小、股骨头类型、髋臼杯大小、髋臼杯倾斜度、髋臼杯内移以及患者相关因素,两侧均相似。在使用标准股骨组件的一侧,平均实际假体偏移(由制造商规格确定)为35.2 mm,放射学偏移为31.5 mm。在使用外侧化股骨组件的一侧,实际假体偏移为42.5 mm,放射学偏移为40.1 mm。两侧偏移的差异具有统计学意义。股骨术前平均偏移为38.8 mm。回归分析显示,只有股骨组件偏移和髋臼杯大小与线性磨损率显著相关。在使用标准股骨组件的一侧线性磨损率为每年0.21 mm,而在使用外侧化股骨组件的一侧线性磨损率为每年0.10 mm。线性磨损率的差异具有显著性。本系列中股骨组件的外侧化更接近恢复术前髋关节生物力学,并显著降低了聚乙烯磨损。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验