Two serotyping assays for hepatitis C virus (Serotyping 1-6 assay; Murex, UK and RIBA Serotyping SI; Chiron, USA) were compared to a standardized genotyping assay (Inno-LiPA HCV II; Innogenetics, Belgium) using serum samples collected from 126 patients chronically infected with hepatitis C virus. Serotyping was positive in 87% and 80% of the samples tested with Murex and Chiron, respectively, and concordant with genotyping in 93% and 88%, respectively. Sequence analysis of the NS5b region of 15 samples with discrepant typing results confirmed the Inno-LiPA finding in all instances. The Murex enzyme immunoassay serotyping method was less sensitive for identifying genotype 2 (P<0.05). The concordance with genotyping of the RIBA serotyping method was lower for genotype 2 than for the other genotypes (P<0.05).

摘要

将两种丙型肝炎病毒血清分型检测方法(血清分型1 - 6检测法;英国Murex公司和RIBA血清分型SI;美国Chiron公司)与一种标准化基因分型检测方法(Inno - LiPA HCV II;比利时Innogenetics公司)进行比较,使用从126例慢性丙型肝炎病毒感染患者采集的血清样本。分别用Murex和Chiron检测的样本中,血清分型阳性率分别为87%和80%,与基因分型的一致性分别为93%和88%。对15例分型结果不一致的样本的NS5b区域进行序列分析,在所有情况下均证实了Inno - LiPA的结果。Murex酶免疫分析血清分型方法在鉴定2型基因型时敏感性较低(P<0.05)。RIBA血清分型方法与基因分型的一致性在2型基因型中低于其他基因型(P<0.05)。