Suppr超能文献

在体外模型中,静脉周围应用纤维蛋白胶可减少人隐静脉移植血管壁的早期损伤。

Perivenous application of fibrin glue reduces early injury to the human saphenous vein graft wall in an ex vivo model.

作者信息

Stooker W, Niessen H W M, Wildevuur W R, van Hinsbergh V W M, Fritz J, Jansen E K, Wildevuur Ch R H, Eijsman L

机构信息

Department of Cardiac Surgery, University Hospital Vrije Universiteit, Amsterdam, The Netherlands.

出版信息

Eur J Cardiothorac Surg. 2002 Feb;21(2):212-7. doi: 10.1016/s1010-7940(01)01121-6.

Abstract

OBJECTIVES

From animal and clinical studies it is known that prevention of 'over-distention' of vein grafts by using extravascular support ameliorates the arterialization process in vein grafts with subsequent more favorable patency. The most ideal support is a biodegradable, porous, elastic graft (Biomaterials, 15 (1994) 83). However, a specific graft meeting these criteria is not available yet. Fibrin glue on the other hand, although used for other purposes in cardiac surgery, theoretically meets the criteria for ideal extravascular support. In this ex vivo study, we evaluated the possible beneficial effect of perivenous application of fibrin glue.

METHODS

Segments of human vein graft obtained during CABG procedures in 14 consecutive patients were placed in a side loop of the extracorporeal perfusion circuit. In this way the study vein grafts did meet identical circumstances as the vein grafts implanted. Perfusion in the loop was started with a flow just enough to counteract the collapse of the vein, usually about 8 mm Hg, and alternately around the segments fibrin glue was applied or no perivenous support was administered as control. After 1 min of soldification, perfusion was started with a pressure of about 60 mm Hg (non-pulsatile flow). Perfusion was maintained for 60 min, after which the grafts were collected for light microscopic and electron microscopic assessment.

RESULTS

Light microscopy and electron microscopy showed remarkable attenuation of endothelial cell loss and less injury of smooth muscle cells of the circular muscle layer of the media in the fibrin glue supported vein grafts compared to the non-supported group.

CONCLUSION

Fibrin glue is able to accomplish adequate external vein graft support, preventing overdistention, in an ex vivo model. This provides a basis for clinical application. Further investigation is necessary to evaluate long-term effects.

摘要

目的

从动物和临床研究可知,通过使用血管外支撑来预防静脉移植物的“过度扩张”,可改善静脉移植物的动脉化过程,进而使通畅率更理想。最理想的支撑物是一种可生物降解、多孔且有弹性的移植物(《生物材料》,1994年第15卷,第83页)。然而,目前尚无符合这些标准的特定移植物。另一方面,纤维蛋白胶虽然在心脏手术中有其他用途,但理论上符合理想血管外支撑的标准。在这项体外研究中,我们评估了静脉周围应用纤维蛋白胶可能产生的有益效果。

方法

从14例连续接受冠状动脉旁路移植术(CABG)的患者获取的人静脉移植物片段,被置于体外循环回路的侧支循环中。通过这种方式,研究中的静脉移植物与植入的静脉移植物处于相同的环境。回路中的灌注开始时,流量刚好足以抵消静脉的塌陷,通常约为8毫米汞柱,然后交替地在片段周围应用纤维蛋白胶或不给予静脉周围支撑作为对照。固化1分钟后,开始以约60毫米汞柱的压力进行灌注(非搏动性血流)。灌注维持60分钟,之后收集移植物进行光学显微镜和电子显微镜评估。

结果

光学显微镜和电子显微镜显示,与无支撑组相比,纤维蛋白胶支撑的静脉移植物中内皮细胞损失明显减轻,中膜环形肌层的平滑肌细胞损伤也较小。

结论

在体外模型中,纤维蛋白胶能够实现对静脉移植物的充分外部支撑,防止过度扩张。这为临床应用提供了依据。有必要进行进一步研究以评估长期效果。