Suppr超能文献

收缩期峰值速度多普勒指数最恰当地反映了完整脑自动调节的动态时间过程。

Peak systolic velocity Doppler index reflects most appropriately the dynamic time course of intact cerebral autoregulation.

作者信息

Rosengarten B, Kaps M

机构信息

Department of Neurology, Faculty of Medicine, Justus Liebig University of Giessen, Germany.

出版信息

Cerebrovasc Dis. 2002;13(4):230-4. doi: 10.1159/000057848.

Abstract

BACKGROUND

Transcranial Doppler sonography measures blood flow velocity in basal cerebral vessels with high accuracy and time resolution. Dynamic blood flow tests were used to investigate functional integrity of the cerebral autoregulation (CA) mechanism. It is known from cortical activation studies that velocity indices differ in their appropriateness to measure changes in blood flow velocity. We aimed to compare the peak systolic, end diastolic and time-averaged mean flow velocity indices for their use in measuring the effectiveness of the CA mechanism.

METHODS

We performed the leg cuff test to induce in 15 healthy volunteers (aged 24.8 +/- 0.4 years, 9 males) CA due to a sudden arterial blood pressure decrease. Data from the middle and posterior cerebral arteries were measured continuously with transcranial Doppler ultrasound, and the arterial blood pressure with a noninvasive photoplethysmographic method. After transforming all variables to relative changes, velocity-pressure diagrams were calculated for each velocity-pressure index. Additionally, we calculated the autoregulation index.

RESULTS

The step decrease in arterial blood pressure resulted in an initial drop, which is followed by a rapid recovery of cerebral blood flow velocity. The autoregulation index was 5.5 +/- 1. Efficacy of CA is illustrated more accurately by peak systolic velocity-pressure curves, which lie continuously above a passive velocity-pressure relationship assuming CA to be absent.

CONCLUSIONS

Our data show peak systolic blood flow velocity index to be most accurate for measuring effectiveness of the dynamic CA mechanism. No differences in the CA were found between the vascular territory of the middle and posterior cerebral arteries.

摘要

背景

经颅多普勒超声检查能高精度、高时间分辨率地测量脑基底血管中的血流速度。动态血流测试用于研究脑自动调节(CA)机制的功能完整性。从皮质激活研究可知,速度指标在测量血流速度变化的适用性方面存在差异。我们旨在比较收缩期峰值、舒张期末期和时间平均平均流速指标在测量CA机制有效性方面的应用。

方法

我们对15名健康志愿者(年龄24.8±0.4岁,9名男性)进行腿部袖带试验,以因动脉血压突然下降诱导CA。用经颅多普勒超声连续测量大脑中动脉和大脑后动脉的数据,并用无创光电容积描记法测量动脉血压。将所有变量转换为相对变化后,为每个速度-压力指标计算速度-压力图。此外,我们还计算了自动调节指数。

结果

动脉血压的阶梯式下降导致最初的下降,随后脑血流速度迅速恢复。自动调节指数为5.5±1。收缩期峰值速度-压力曲线能更准确地说明CA的有效性,这些曲线持续位于假设不存在CA时的被动速度-压力关系之上。

结论

我们的数据表明,收缩期峰值血流速度指数在测量动态CA机制的有效性方面最为准确。大脑中动脉和大脑后动脉的血管区域之间在CA方面未发现差异。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验