BACKGROUND AND PURPOSE

Second harmonic imaging (SHI) is a novel ultrasound technique that allows the evaluation of brain tissue perfusion. The purpose of this study was to assess normal cerebral echo contrast characteristics in 3 regions of interest (ROIs) in the transverse axial and coronal insonation planes through the temporal bone window. Materials and Methods- SHI examinations were performed in 25 patients without cerebrovascular disease (aged 50+/-19 years) in a transverse axial and a coronal diencephalic insonation plane through the temporal bone window. After intravenous administration of 2.5 g (400 mg/mL) of a galactose-based echo contrast agent, 62 time-triggered images with a transmission rate of 1 frame per 2.5 seconds were recorded for offline analysis. Time-intensity curves, including peak intensity (PI) (dB) and positive gradient (PG) (dB/s), were calculated to quantify ultrasound intensity in 3 different ROIs in both planes of the following sections: the thalamus (ROI(thal)), the lentiform nucleus (ROI(ncl)), and the area supplied by the middle cerebral artery (ROI(mca)).

RESULTS

Characteristic time-intensity curves with high PIs and steep PGs were recorded in each ROI. Statistical analysis of the aforementioned parameters showed no significant difference for comparison of the 3 ROIs in the transverse axial versus the coronal insonation plane. Comparison of different ROIs in the transverse axial insonation plane revealed that PI was significantly higher in ROI(thal) than in ROI(mca) (7.8 versus 5.5 dB; P<0.05) and significantly higher in ROI(ncl) than in ROI(thal) (9.3 versus 7.8 dB; P<0.05). In contrast, PG was comparable in ROI(thal) and in ROI(mca) (0.21 versus 0.25 dB/s; P=0.42).

CONCLUSIONS

SHI is a promising technique for the evaluation of cerebral parenchymal perfusion. Comparison of the transverse axial and coronal insonation planes shows similar time-intensity curves with comparable values for PIs and PGs. Coronal insonation allows the evaluation of perfusion abnormalities near the vertex and skull base, areas that cannot be depicted in the transverse axial plane. Comparison of the different ROIs indicates that the PG is a more robust and reliable parameter than the PI.

摘要

背景与目的

二次谐波成像(SHI)是一种新型超声技术,可用于评估脑组织灌注。本研究旨在通过颞骨窗,在横向轴向和冠状位声束平面的3个感兴趣区域(ROI)中评估正常脑回声对比特征。材料与方法:对25例无脑血管疾病的患者(年龄50±19岁),通过颞骨窗在横向轴向和冠状位间脑声束平面进行SHI检查。静脉注射2.5 g(400 mg/mL)基于半乳糖的回声造影剂后,以每2.5秒1帧的传输速率记录62幅时间触发图像用于离线分析。计算时间-强度曲线,包括峰值强度(PI)(dB)和正梯度(PG)(dB/s),以量化以下各节两个平面中3个不同ROI的超声强度:丘脑(ROI(thal))、豆状核(ROI(ncl))和大脑中动脉供血区(ROI(mca))。

结果

每个ROI均记录到具有高PI和陡峭PG的特征性时间-强度曲线。对上述参数的统计分析表明,横向轴向与冠状位声束平面中3个ROI的比较无显著差异。横向轴向声束平面中不同ROI的比较显示,ROI(thal)中的PI显著高于ROI(mca)(7.8对5.5 dB;P<0.05),ROI(ncl)中的PI显著高于ROI(thal)(9.3对7.8 dB;P<0.05)。相比之下,ROI(thal)和ROI(mca)中的PG相当(0.21对0.25 dB/s;P = 0.42)。

结论

SHI是一种有前景的评估脑实质灌注的技术。横向轴向和冠状位声束平面的比较显示,时间-强度曲线相似,PI和PG值相当。冠状位声束检查可评估头顶和颅底附近的灌注异常,这些区域在横向轴向平面无法显示。不同ROI的比较表明,PG是比PI更稳健、可靠的参数。