Schwiegerling Jim
Department of Ophthalmology, University of Arizona, Tucson 85711, USA.
J Opt Soc Am A Opt Image Sci Vis. 2002 Oct;19(10):1937-45. doi: 10.1364/josaa.19.001937.
Recent developments in technologies to correct aberrations in the eye have fostered extensive research in wave-front sensing of the eye, resulting in many reports of Zernike expansions of wave-front errors of the eye. For different reports of Zernike expansions, to be compared, the same pupil diameter is required. Since no standard pupil size has been established for reporting these results, a technique for converting Zernike expansion coefficients from one pupil size to another is needed. This investigation derives relationships between the Zernike expansion coefficients for two different pupil sizes.
近年来,用于矫正眼睛像差的技术发展推动了对眼睛波前传感的广泛研究,从而产生了许多关于眼睛波前误差的泽尼克展开式的报告。为了比较不同的泽尼克展开式报告,需要相同的瞳孔直径。由于尚未确立用于报告这些结果的标准瞳孔尺寸,因此需要一种将泽尼克展开系数从一种瞳孔尺寸转换为另一种瞳孔尺寸的技术。本研究推导了两种不同瞳孔尺寸的泽尼克展开系数之间的关系。