电子束CT测量主动脉瓣钙化的可重复性。

Reproducibility of electron-beam CT measures of aortic valve calcification.

作者信息

Budoff Matthew J, Mao Songshou, Takasu Junichiro, Shavelle David M, Zhao Xue-Qiao, O'Brien Kevin D

机构信息

Harbor-UCLA Research and Education Institute, Torrance, Calif, USA.

出版信息

Acad Radiol. 2002 Oct;9(10):1122-7. doi: 10.1016/s1076-6332(03)80513-5.

Abstract

RATIONALE AND OBJECTIVES

The authors performed this study to establish the interscan, interobserver, and intraobserver reproducibility of aortic valve calcification (AVC) measurements obtained with electron-beam computed tomography (CT).

MATERIALS AND METHODS

The authors evaluated electron-beam CT scans from all patients who had undergone two serial examinations on the same day as part of a study of coronary artery calcification reproducibility. In patients in whom aortic valve calcium was identified at electron-beam CT, AVC scores were measured with both the Agatston and the volumetric methods, which were developed previously to quantify coronary calcium.

RESULTS

Forty-four asymptomatic patients (mean age, 66 years +/- 9) with AVC at electron-beam CT were included in the analyses. AVC score reproducibility was excellent with both the Agatston and the volumetric methods (R2 = 0.99, P = .0001 for both), with median interscan variabilities of 7% and 6.2%, respectively. Interscan reproducibility was similar, whether the analysis included all scans or was restricted to those with scores greater than 10 or greater than 30. For the volumetric method, the median interobserver variability was 5% and the median intraobserver variability was 1%.

CONCLUSION

The low interscan, interobserver, and intraobserver variabilities at electron-beam CT suggest that this method should be useful for the noninvasive monitoring of AVC changes over time and for assessing the efficacy of therapies aimed at slowing AVC accumulation.

摘要

原理与目的

作者开展本研究以确定用电子束计算机断层扫描(CT)获得的主动脉瓣钙化(AVC)测量值的扫描间、观察者间和观察者内的可重复性。

材料与方法

作者评估了作为冠状动脉钙化可重复性研究一部分,于同一天接受两次连续检查的所有患者的电子束CT扫描。在电子束CT检查中发现主动脉瓣钙化的患者,采用之前开发的用于量化冠状动脉钙化的阿加斯顿法和容积法测量AVC评分。

结果

分析纳入了44例电子束CT显示有AVC的无症状患者(平均年龄66岁±9岁)。阿加斯顿法和容积法的AVC评分可重复性均极佳(两者R2 = 0.99,P = 0.0001),扫描间变异性中位数分别为7%和6.2%。无论分析包括所有扫描还是仅限于评分大于10或大于30的扫描,扫描间可重复性均相似。对于容积法,观察者间变异性中位数为5%,观察者内变异性中位数为1%。

结论

电子束CT的扫描间、观察者间和观察者内低变异性表明,该方法对于无创监测AVC随时间的变化以及评估旨在减缓AVC积累的治疗效果应是有用的。