Suppr超能文献

股四头肌霍夫曼反射的组内和组间可靠性。

Intrasession and intersession reliability of the quadriceps Hoffmann reflex.

作者信息

Hopkins J Ty, Wagie N C

机构信息

School of Kinesiology and Recreation, Illinois State University, Normal, IL, USA.

出版信息

Electromyogr Clin Neurophysiol. 2003 Mar;43(2):85-9.

Abstract

The Hoffmann reflex (H-reflex) is a resting electromyographic (EMG) measurement of motoneuron pool recruitment. While the soleus H-reflex has been studied extensively, the study of the quadriceps H-reflex has been limited for various reasons. To date no data exist regarding the reliability of this measurement within and between sessions over an extended period of time. The purpose of this study was to establish quadriceps H-reflex reliability over a four-week period consisting of 6 testing sessions. Eleven neurologically sound volunteers (age: 20 +/- 2 yr, height: 181.9 +/- 9.9 cm; mass: 84.2 +/- 17.8 Kg) participated in this study. Subjects were prepared for EMG surface electrodes over the vastus medialis and medial malleolus (ground). A stimulating bar electrode was placed over the femoral nerve, and a stimulus was delivered at 20 sec intervals with increasing amplitude to obtain a peak quadriceps H-reflex. Ten peak H-reflex measurements were recorded for each session. The stimulator amplitude was increased further to obtain the peak efferent motor response (M-response) for normalization of peak H-reflex measurements. The procedure was repeated at 1 hr, 24 hr, 1, 2, and 3 weeks following the initial session. Intraclass correlation coefficients (ICC (2.1) and ICC (3.1)) were calculated using normalized peak H-reflex measurements. Strong reliability was detected within a session (10 trials ICC (2.1) = 0.957, ICC (3.1) = 0.970; 5 trials ICC (2.1) = 0.961, (ICC (3.1) = 0.970). ICC (2.1) calculations yielded strong reliability between the first and second (1 hr) session (0.956) but moderate reliability between days 1 and 2 (0.787) and between all session over 4 weeks (0.756). ICC (3.1) calculations were also computed to determine the reliability for the fixed selection of sessions. This calculation yielded strong reliabilities between days 1 and 2 (0.969) and between all sessions over 4 weeks (0.911). Within a measurement session quadriceps H-reflex measurements are very reliable, and we recommend 5 trials to establish a measurement. Between measurement sessions these data provide evidence of strong reliability for these fixed sessions (ICC (3.1)), and generalized evidence for moderate reliability over a 4-week period has also been provided (ICC (2.1)). These data provide valuable information for the researcher and practitioner as to the reliability of this measurement in detecting changes in the neuromuscular system.

摘要

霍夫曼反射(H反射)是对运动神经元池募集情况的一种静息肌电图(EMG)测量。虽然比目鱼肌H反射已得到广泛研究,但由于各种原因,股四头肌H反射的研究一直有限。迄今为止,尚无关于该测量在较长时间段内不同测量时段之间及测量时段内可靠性的数据。本研究的目的是确定在为期四周、包含6次测试时段的时间内股四头肌H反射的可靠性。11名神经功能健全的志愿者(年龄:20±2岁,身高:181.9±9.9厘米;体重:84.2±17.8千克)参与了本研究。在受试者的股内侧肌和内踝(接地)处准备好用于肌电图的表面电极。将刺激条形电极置于股神经上方,并以20秒的间隔施加递增幅度的刺激,以获得股四头肌H反射峰值。每次测试时段记录10次H反射峰值测量结果。进一步增加刺激器幅度以获得传出运动反应峰值(M反应),用于对H反射峰值测量进行标准化。在初始测试时段后的1小时、24小时、1周、2周和3周重复该过程。使用标准化的H反射峰值测量结果计算组内相关系数(ICC(2.1)和ICC(3.1))。在一个测试时段内检测到很强的可靠性(10次试验ICC(2.1)=0.957,ICC(3.1)=0.970;5次试验ICC(2.1)=0.961,ICC(3.1)=0.970)。ICC(2.1)计算得出第一次和第二次(1小时)测试时段之间具有很强的可靠性(0.956),但第1天和第2天之间为中等可靠性(0.787),以及4周内所有测试时段之间为中等可靠性(0.756)。还计算了ICC(3.1)以确定固定选择测试时段的可靠性。该计算得出第1天和第2天之间具有很强的可靠性(0.969),以及4周内所有测试时段之间具有很强的可靠性(0.911)。在一个测量时段内,股四头肌H反射测量非常可靠,我们建议进行5次试验来确定一次测量结果。在不同测量时段之间,这些数据为这些固定测试时段提供了很强可靠性的证据(ICC(3.1)),同时也提供了4周内中等可靠性的一般性证据(ICC(2.1))。这些数据为研究人员和从业者提供了关于该测量在检测神经肌肉系统变化方面可靠性的有价值信息。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验