Akishita M, Ouchi Y, Kozaki K, Orimo A, Hattori A, Orimo H
Department of Geriatrics, Faculty of Medicine, University of Tokyo, Japan.
Jpn Heart J. 1992 Sep;33(5):631-41. doi: 10.1536/ihj.33.631.
This study was undertaken to investigate the accuracy and reliability of videodensitometry (VDM) in measuring the magnitude of coronary arterial stenosis on coronary angiogram (CAG). CAG taken after administration of sublingual nitroglycerin was analyzed with VDM (XR-70 Coronary Analyzer, Vanguard). The magnitude of stenosis in coronary segments with four different classes of stenosis was consecutively measured 10 times by the same observer, and the values were 89.0 +/- 1.4, 70.9 +/- 2.1, 59.5 +/- 2.5, and 22.8 +/- 3.4%. The coefficients of variation (CVs), indicating intraobserver variability, were low for severe to moderate lesions (1.6, 2.9, and 4.3%, respectively), but was higher for low-grade lesions (14.8%). When the same lesions were measured by 2 observers, the measurements were highly correlated (r = 0.971, p < 0.01). The results of VDM were consistent with those of conventional gross examination for moderate to severe lesions, and the discrepancy was mainly found in low-grade lesions. The magnitude of stenosis of the same lesion was measured from the right and the left anterior oblique views, and the cineangle was found not to affect the results of VDM. Moreover, cardiac cycle did not affect the videodensitometric measurements of % area stenosis. In order to further investigate the accuracy of VDM, the magnitude of stenosis was measured in nine phantom arteries, and the value measured by VDM significantly correlated with the actual stenosis (r = 0.969, p < 0.001). These results indicate that the values of coronary arterial stenosis on CAG measured by VDM are accurate and clinically acceptable, even though variability is somewhat high for low grade lesions. VDM may be useful for evaluation of the outcome of PTCA and the anti-atherogenic action of some agents.
本研究旨在探讨视频密度测定法(VDM)在冠状动脉造影(CAG)上测量冠状动脉狭窄程度的准确性和可靠性。使用VDM(XR - 70冠状动脉分析仪,Vanguard)对舌下含服硝酸甘油后进行的CAG进行分析。由同一观察者对具有四种不同狭窄程度类别的冠状动脉节段的狭窄程度连续测量10次,其值分别为89.0±1.4、70.9±2.1、59.5±2.5和22.8±3.4%。表示观察者内变异性的变异系数(CV),对于重度至中度病变较低(分别为1.6%、2.9%和4.3%),但对于轻度病变较高(14.8%)。当两名观察者测量相同病变时,测量结果高度相关(r = 0.971,p < 0.01)。VDM的结果与中度至重度病变的传统大体检查结果一致,差异主要存在于轻度病变中。从右前斜位和左前斜位测量同一病变的狭窄程度,发现电影角度不影响VDM的结果。此外,心动周期不影响%面积狭窄的视频密度测定测量。为了进一步研究VDM的准确性,在九条模拟动脉中测量狭窄程度,VDM测量的值与实际狭窄程度显著相关(r = 0.969,p < 0.001)。这些结果表明,尽管轻度病变的变异性有所偏高,但VDM测量的CAG上冠状动脉狭窄值是准确的且在临床上可接受。VDM可能有助于评估经皮冠状动脉腔内血管成形术(PTCA)的结果以及某些药物的抗动脉粥样硬化作用。