Cebi Niyazi, Frömke Johannes, Walterbusch Gerd
Department of Thoracic and Cardiovascular Surgery, St.-Johannes-Hospital Dortmund, Dortmund, Germany.
Ann Thorac Surg. 2003 Aug;76(2):631-2. doi: 10.1016/s0003-4975(03)00026-2.
Bleeding from a coronary anastomosis and aortic annulus is sometimes a problem in the technique for aortic root replacement described by Bentall and DeBono and Cabrol and colleagues. Exposure and repair of these suture lines may be quite difficult after the termination of bypass. This article describes a new technique for aortic root replacement. In our experience to date, 6 patients with aneurysm of the ascending aorta and root and a calcified aortic valve stenosis as well as 1 patient with aortic dissection type A have benefited from this new procedure.
在Bentall和DeBono以及Cabrol及其同事所描述的主动脉根部置换技术中,冠状动脉吻合口和主动脉瓣环出血有时是个问题。体外循环结束后,暴露和修复这些缝合线可能相当困难。本文描述了一种新的主动脉根部置换技术。根据我们目前的经验,6例升主动脉和主动脉根部瘤合并钙化性主动脉瓣狭窄的患者以及1例A型主动脉夹层患者从这一新手术中获益。