Indoor health: background levels of fungi.

作者信息

Gots Ronald E, Layton Nancy J, Pirages Suellen W

机构信息

International Center for Toxicology and Medicine, 2301 Research Blvd., Suite 210, Rockville, MD 20850, USA.

出版信息

AIHA J (Fairfax, Va). 2003 Jul-Aug;64(4):427-38. doi: 10.1202/396.1.

Abstract

There is no uniformity in the suggested guidelines for acceptable levels of fungi in indoor ambient air. Thus, health professionals have no way to determine what levels of fungi may pose a threat to human health. The authors reviewed the published literature to identify data reported for noncomplaint structures, that is, structures in which occupants did not have health concerns associated with the quality of the indoor air. For both commercial and residential structures, fungal concentrations detected were often higher than currently suggested guidance values. The average indoor air concentration in 149 noncomplaint commercial buildings was 233 colony forming units (CFU) per cubic meter, whereas outdoor ambient air levels averaged 983 CFU/m(3). Total indoor spore counts ranged from 610 to 1040 spores/m(3) in three commercial buildings. Outdoor total spore counts associated with these buildings ranged from 400 to 80,000 spores/m(3). The average indoor concentration reported for 820 noncomplaint residential structures was 1252 CFU/m(3) with an average outdoor level of 1524 CFU/m(3). Total spore counts detected indoors at 85 residential structures ranged from 68 to 2307 spores/m(3). Outdoor spore levels associated with these structures ranged from 400 to 80,000 spores/m(3). A large proportion of both commercial and residential noncomplaint structures have indoor ambient air fungal concentrations above 500 CFU/m(3), a level often advocated as requiring remediation in structures when occupants complain of nonspecific adverse health symptoms.

摘要

关于室内环境空气中可接受的真菌水平,所建议的指导方针并不统一。因此,卫生专业人员无法确定何种真菌水平可能对人类健康构成威胁。作者查阅了已发表的文献,以找出针对不符合标准的建筑物所报告的数据,即居住者未对室内空气质量表示健康担忧的建筑物。对于商业和住宅建筑,检测到的真菌浓度往往高于目前建议的指导值。149栋不符合标准的商业建筑中,室内空气平均浓度为每立方米233个菌落形成单位(CFU),而室外环境空气水平平均为983 CFU/m³。在三栋商业建筑中,室内孢子总数在610至1040个孢子/m³之间。与这些建筑相关的室外孢子总数在400至80000个孢子/m³之间。820栋不符合标准的住宅建筑报告的室内平均浓度为1252 CFU/m³,室外平均水平为1524 CFU/m³。在85栋住宅建筑中检测到的室内孢子总数在68至2307个孢子/m³之间。与这些建筑相关的室外孢子水平在400至80000个孢子/m³之间。很大一部分商业和住宅不符合标准的建筑,其室内环境空气中的真菌浓度高于500 CFU/m³,当居住者抱怨出现非特异性不良健康症状时,这一水平通常被认为该建筑需要进行整治。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验