Suppr超能文献

采用单纯切除及金属夹法对结肠无蒂肿瘤进行内镜黏膜切除术。

Endoscopic mucosal resection using a pure cut and hemoclip method for colonic nonpolypoid neoplasms.

作者信息

Hsu Chen-Ming, Ho Yu-Pin, Lien Jau-Min, Su Ming-Yao, Chiu Cheng-Tang, Chen Pang-Chi, Huang Shiu-Feng

机构信息

Division of Gastroenterology, Department of Internal Medicine, Chang Gung Memorial Hospital, Taipei, Taiwan, ROC.

出版信息

Chang Gung Med J. 2003 Aug;26(8):586-91.

Abstract

BACKGROUND

Colonic mucosal neoplastic lesions can be classified morphologically into polypoid and nonpolypoid types. The nonpolypoid type has a greater malignancy potential than does the polypoid type. Removing these lesions and obtaining an integral specimen for histopathologic assessment during colonoscopy are very important. This study evaluates the safety and integrity of specimens obtained by endoscopic mucosal resection (EMR) using the pure cut current and hemoclip method.

METHODS

Fourteen nonpolypoid colonic neoplasms, which were removed by EMR using the pure cut and hemoclip method between April 2001 and April 2002, were studied. There were 9 male and 4 female patients and the mean age was 57.8 +/- 15.5 (range, 32 - 80) years. EMR was conducted in cases where the lesions were diagnosed as neoplastic tumors by magnification colonoscopy and the indigo carmine dye spray method.

RESULTS

The study revealed 11 flat type neoplasms and 3 laterally spreading tumors. The mean size of the lesions was 10.7 +/- 5.6 (range, 6 - 25) mm. All lesions were completely removed. Histopathologically, there were 1 adenocarcinoma and 13 adenomas (3 with mild dysplasia, 7 with moderate dysplasia, and 3 with severe dysplasia). The mean number of hemoclips used was 2.14 +/- 0.66 (range, 1 - 3) pieces. No bleeding or perforation was noted following EMR.

CONCLUSION

EMR using the pure cut and hemoclip method is a useful means of obtaining an integral specimen for accurate pathologic assessment. This method provides a safe and minimally invasive technique for managing colonic non-polypoid lesions.

摘要

背景

结肠黏膜肿瘤性病变在形态学上可分为息肉样和非息肉样类型。非息肉样类型的恶性潜能高于息肉样类型。在结肠镜检查时切除这些病变并获取完整标本进行组织病理学评估非常重要。本研究评估了使用纯切割电流和止血夹法进行内镜黏膜切除术(EMR)所获取标本的安全性和完整性。

方法

对2001年4月至2002年4月间使用纯切割和止血夹法通过EMR切除的14例非息肉样结肠肿瘤进行了研究。患者中男性9例,女性4例,平均年龄为57.8±15.5(范围32 - 80)岁。对于经放大结肠镜检查和靛胭脂染色法诊断为肿瘤性肿瘤的病变进行EMR。

结果

研究发现11例平坦型肿瘤和3例侧向扩散肿瘤。病变的平均大小为10.7±5.6(范围6 - 25)mm。所有病变均被完全切除。组织病理学检查显示有1例腺癌和13例腺瘤(3例轻度发育异常,7例中度发育异常,3例重度发育异常)。使用止血夹的平均数量为2.14±0.66(范围1 - 3)枚。EMR后未发现出血或穿孔。

结论

使用纯切割和止血夹法的EMR是获取完整标本以进行准确病理评估的有用方法。该方法为处理结肠非息肉样病变提供了一种安全且微创的技术。