van de Sande M A J, Rozing P M
Department of Orthopaedics, Leiden University Medical Center, The Netherlands.
Int Orthop. 2004 Apr;28(2):115-8. doi: 10.1007/s00264-004-0537-2.
Between 1994 and 2001, a short-stemmed modular shoulder prosthesis was inserted in 62 shoulders in patients with rheumatoid arthritis (RA) or osteoarthrosis (OA). We reviewed 53 patients with 60 shoulders (45 RA/15 OA) with at least 24 months follow-up. In 22 shoulders, we used a total shoulder prosthesis including a glenoid polyethylene component, whereas 38 shoulders only had a humeral component. In six shoulders, the humeral component was cemented. The average follow-up was 47 (24-99) months. There were no intraoperative complications but one wound infection and one patient with proximal migration of the humeral component. Hospital for Special Surgery Score increased from 44(19-72) to 63 (21-93) points and Shoulder Function Assessment score (SFA) from 24 (12-46) to 42 (11-66)points. The VAS score for pain at rest improved from 4.3 to 1.9. Nonprogressive radiolucent lines were seen adjacent to nine glenoid and one humeral components. Fifty-six patients were satisfied with the result.
1994年至2001年间,62例类风湿性关节炎(RA)或骨关节炎(OA)患者的肩部植入了短柄模块化人工肩关节假体。我们对53例患者的60个肩部(45例RA/15例OA)进行了至少24个月的随访。22个肩部使用了全肩关节假体,包括一个关节盂聚乙烯部件,而38个肩部仅植入了肱骨部件。6个肩部的肱骨部件采用骨水泥固定。平均随访时间为47(24 - 99)个月。术中无并发症,但有1例伤口感染和1例肱骨部件近端移位的患者。特殊外科医院评分从44(19 - 72)分提高到63(21 - 93)分,肩部功能评估评分(SFA)从24(12 - 46)分提高到42(11 - 66)分。静息时疼痛的视觉模拟评分(VAS)从4.3改善至1.9。9个关节盂部件和1个肱骨部件周围可见无进展性的透亮线。56例患者对结果满意。