Koenigsberg Robert A, Vakil Nakul, Hong Tom A, Htaik Tun, Faerber Eric, Maiorano Tina, Dua Monica, Faro Scott, Gonzales Carlos
Department of Radiologic Sciences, Drexel University College of Medicine, Philadelphia, PA 19102-1192, USA.
AJNR Am J Neuroradiol. 2005 Jan;26(1):89-92.
Platybasia, or abnormal obtuseness of the basal angle, was first measured on plain skull images. At present, evaluation of the brain and skull more commonly involves CT and MR imaging. We evaluated a new MR imaging method of evaluating platybasia.
We retrospectively evaluated midline sagittal MR images in 200 adults and 50 children. The basal angle of the skull base was measured by using two methods: The standard MR imaging technique measured the angle formed by two lines-one joining the nasion and the center of the pituitary fossa connected by a line joining the anterior border of the foramen magnum and center of the pituitary fossa. The modified technique measured the angle formed by a line across the anterior cranial fossa and dorsum sellae connecting a line along the clivus.
With the standard MR imaging technique, we obtained mean angles of 129 degrees +/- 6 degrees for adults and 127 degrees +/- 5 degrees for children, compared with 135.3 degrees (composite mean) in previous series. The modified technique produced values of 117 degrees +/- 6 degrees for adults and 114 degrees +/- 5 degrees for children, which were significantly lower that those of standard MR imaging and traditional radiography (P <.05).
Both the standard and modified MR imaging techniques produced basal angles lower than those previously reported with standard radiography. The modified technique uses clearly featured landmarks that can be reproduced consistently on midline sagittal T1 images. This technique and its corresponding values can be used as the new standard for evaluating the basal angle.
扁平颅底,即颅底角异常钝圆,最初是在普通颅骨影像上测量的。目前,对脑和颅骨的评估更常用CT和磁共振成像(MR)。我们评估了一种用于评估扁平颅底的新MR成像方法。
我们回顾性评估了200名成人和50名儿童的中线矢状面MR图像。采用两种方法测量颅底角:标准MR成像技术测量由两条线形成的角度,一条线连接鼻根点和垂体窝中心,另一条线连接枕骨大孔前缘和垂体窝中心。改良技术测量由一条穿过前颅窝和鞍背的线与一条沿斜坡的线连接形成的角度。
采用标准MR成像技术,成人的平均角度为129°±6°,儿童为127°±5°,而先前系列报道的综合平均值为135.3°。改良技术得出成人的值为117°±6°,儿童为114°±5°,显著低于标准MR成像和传统放射摄影的值(P<.05)。
标准和改良的MR成像技术得出的颅底角均低于先前标准放射摄影报道的值。改良技术使用的标志性特征清晰,可在中线矢状面T1图像上一致重现。该技术及其相应的值可作为评估颅底角的新标准。