Hydroxyapatite (HA) are commonly applied to orthopaedic implants for acceleration of osteointegration and so overcoming the loosening problems such as in cortical screws. Electrophoretic deposition (EPD) of hydroxyapatite was applied for coating of cortical screws in this work. The effects of hydroxyapatite-coated and uncoated cortical screws on insertion and extraction torque were investigated through in vivo experiments. Three groups of screws were undertaken: first group with no coating, second group coated with HA and the third group coated with HA+interlayer, a synthetic calcium silicate compound. Five sheep were operated, and 60 cortical (20 x 3) screws from those of groups were implanted in cortical femurs to observe the effect of HA and interlayer on screws. Results show that as an alternative to plasma spray coating method, the EPD process enables to produce a quick, easy, cheap and uniform adjustable coating layer. Also from biomechanical and SEM examinations, HA coating by EPD method of cortical screws resulted in extremely improved fixation with reduced risk of loosening problem.
羟基磷灰石(HA)通常应用于骨科植入物,以加速骨整合,从而克服诸如皮质骨螺钉松动等问题。在本研究中,采用羟基磷灰石的电泳沉积(EPD)法对皮质骨螺钉进行涂层处理。通过体内实验研究了羟基磷灰石涂层和未涂层皮质骨螺钉对插入和拔出扭矩的影响。实验分为三组螺钉:第一组无涂层,第二组涂有HA,第三组涂有HA + 中间层(一种合成硅酸钙化合物)。对五只绵羊进行手术,并将来自这些组的60枚皮质骨螺钉(20×3)植入股骨皮质中,以观察HA和中间层对螺钉的影响。结果表明,作为等离子喷涂涂层方法的替代方法,EPD工艺能够快速、简便、廉价且均匀地制备可调节涂层。此外,通过生物力学和扫描电子显微镜检查发现,采用EPD法对皮质骨螺钉进行HA涂层可显著改善固定效果,降低松动问题的风险。