Shishido F, Uemura K, Murakami M, Inugami A, Ogawa T, Higano S, Fujita H, Shimosegawa E, Kanno I, Aizawa Y
Department of Radiology and Nuclear Medicine, Research Institute for Brain and Blood Vessels-Akita.
Kaku Igaku. 1992 Jan;29(1):27-35.
Technetium-99m ethyl cysteinate dimer (ECD) has recently developed for SPECT imaging in assessment of cerebral perfusion. We evaluated the arterial blood clearance and the regional brain uptake of Tc-99m ECD compared with the regional CBF measured by PET in patients with cerebrovascular disease. Nine patients with diagnosis of cerebral ischemic disorders (N = 7) and cerebral hemorrhage (N = 2) were studied. PET study was performed with HEADTOME IV by O-15 steady state inhalation method. Immediately after the PET study, 555-740 MBq (5-20 mCi) of Tc-99m ECD was injected intravenously. After injection arterial blood sampling was performed sequentially, and we separated lipophilic fraction from whole blood using ethyl acetate in two cases. The SPECT imaging with Tc-99m ECD (ECD-SPECT) was started 5 min (first imaging) and 60 min (second imaging) after the administration using a high resolution ring type SPECT system (HEADTOME II). Several ROIs were placed on practically the same anatomical location on both SPECT and PET images. Clearance of the tracer in arterial whole blood and lipophilic fraction was rapid. Concerning to the distribution pattern of ECD-SPECT images there was no differences between the 1st imaging and the 2nd imaging, although about 15% of diffuse decrease of Tc-99m ECD uptake was shown in the 2nd images. The brain distribution of ECD-SPECT was comparable to the pattern of CBF image by PET. The regional relative counts of ECD-SPECT corresponded closely to the CBF value by PET, but it was no linear correlation between brain uptake of ECD-SPECT and PET-CBF.(ABSTRACT TRUNCATED AT 250 WORDS)
锝-99m 半胱氨酸乙酯二聚体(ECD)最近已被开发用于单光子发射计算机断层显像(SPECT)评估脑灌注。我们比较了脑血管疾病患者中锝-99m ECD 的动脉血清除率和脑局部摄取情况与正电子发射断层显像(PET)测量的局部脑血流量(CBF)。研究了9例诊断为脑缺血性疾病(7例)和脑出血(2例)的患者。PET 研究采用 O-15 稳态吸入法通过 HEADTOME IV 进行。PET 研究后立即静脉注射555 - 740 兆贝可(5 - 20 毫居里)的锝-99m ECD。注射后依次采集动脉血样,在两例中使用乙酸乙酯从全血中分离亲脂部分。使用高分辨率环形 SPECT 系统(HEADTOME II)在给药后5分钟(首次显像)和60分钟(第二次显像)开始进行锝-99m ECD 的 SPECT 显像(ECD-SPECT)。在 SPECT 和 PET 图像上几乎相同的解剖位置放置了几个感兴趣区(ROI)。示踪剂在动脉全血和亲脂部分的清除很快。关于 ECD-SPECT 图像的分布模式,第一次显像和第二次显像之间没有差异,尽管在第二次图像中显示约15%的锝-99m ECD 摄取呈弥漫性下降。ECD-SPECT 的脑分布与 PET 的 CBF 图像模式相当。ECD-SPECT 的局部相对计数与 PET 的 CBF 值密切相关,但 ECD-SPECT 的脑摄取与 PET-CBF 之间没有线性相关性。(摘要截短于250字)