Fang Yi-wen, Hao Zhi-feng, Song Yi-bing, Sun Chang-yong, Yu Jian, Yu Lin
Analysis and Testing Center, Department of Chemistry, Shantou University, Shantou 515063, China.
Guang Pu Xue Yu Guang Pu Fen Xi. 2005 Feb;25(2):280-2.
One gram (+/- 0.0001 g) of lithium hexafluorophosphate was weighed exactly under dry atmosphere and was dissolved with an adequate amount of dimethyl carbonate (DMC). After the sample solution was pretreated with a series of methods, Be, Cu, Pb, Ca, Zr, Co, Mg, V, Ti, Mo, Ni, Mn, Sr, Zn, K, Al, Ba, Cd, Fe, Cr and Na were determined by ICP-AES. The results show that the recoveries of standard addition were 93.3%-102.1%, and the relative standard deviations (n = 11) were 0%-3.56%. The method is efficient, accurate and easy to operate. It has been applied to the determination of lithium hexafluorophosphate products with satisfactory results.
在干燥气氛下精确称取1克(±0.0001克)六氟磷酸锂,并用适量碳酸二甲酯(DMC)溶解。样品溶液经一系列方法预处理后,采用电感耦合等离子体发射光谱法(ICP - AES)测定其中的铍(Be)、铜(Cu)、铅(Pb)、钙(Ca)、锆(Zr)、钴(Co)、镁(Mg)、钒(V)、钛(Ti)、钼(Mo)、镍(Ni)、锰(Mn)、锶(Sr)、锌(Zn)、钾(K)、铝(Al)、钡(Ba)、镉(Cd)、铁(Fe)、铬(Cr)和钠(Na)。结果表明,加标回收率为93.3% - 102.1%,相对标准偏差(n = 11)为0% - 3.56%。该方法高效、准确且易于操作,已应用于六氟磷酸锂产品的测定,结果令人满意。