Suppr超能文献

高分辨率电感耦合等离子体质谱法可快速评估婴幼儿的铁吸收情况。

High resolution inductively coupled plasma mass spectrometry allows rapid assessment of iron absorption in infants and children.

作者信息

Chen Zhensheng, Griffin Ian J, Plumlee Lora M, Abrams Steven A

机构信息

U.S. Department of Agriculture/ARS Children's Nutrition Research Center, Department of Pediatrics, Baylor College of Medicine, Houston, TX 77030, USA.

出版信息

J Nutr. 2005 Jul;135(7):1790-5. doi: 10.1093/jn/135.7.1790.

Abstract

Stable isotope absorption studies of iron have been limited by the high cost and limited availability of isotope ratio analysis using thermal ionization MS (TIMS). The development of high-resolution double focusing inductively coupled plasma MS (ICP-MS) may permit more cost-efficient sample analysis due to its high throughput, lower cost, easy sample pretreatment, and greater availability. Our objective was to develop an ICP-MS methodology for the measurement of iron isotope ratios using very small blood volumes. We developed a technique using multiple iron-nickel mixing standard solutions to adjust for nickel interference calibration. RBC samples from human subjects previously given 58Fe and 57Fe were analyzed for iron isotope ratios and compared with our current methodology (TIMS). Reproducibility of iron isotope ratios provided external relative SD < 0.5 and 0.7% (1 SD) for 57Fe/54Fe and 58Fe/54Fe, respectively. Iron isotope ratios from ICP-MS analysis did not differ from those from TIMS based on statistical analyses, nor did the calculated iron absorption values. The mean and SD of iron absorption did not differ when measured by TIMS or ICP-MS. A 2-microL RBC sample was sufficient for ICP-MS iron isotope ratio analysis with an internal relative SD < 0.5% and analytical time < 5 min. This technique may assist groups in increasing their use of stable isotope methods to assess iron absorption in infants and children.

摘要

铁的稳定同位素吸收研究一直受到使用热电离质谱仪(TIMS)进行同位素比率分析的高成本和有限可用性的限制。高分辨率双聚焦电感耦合等离子体质谱仪(ICP-MS)的发展可能因其高通量、低成本、易于样品预处理以及更高的可用性而允许进行更具成本效益的样品分析。我们的目标是开发一种使用非常少量血液来测量铁同位素比率的ICP-MS方法。我们开发了一种使用多种铁镍混合标准溶液来调整镍干扰校准的技术。对先前给予58Fe和57Fe的人类受试者的红细胞样本进行铁同位素比率分析,并与我们当前的方法(TIMS)进行比较。铁同位素比率的重现性分别为57Fe/54Fe和58Fe/54Fe提供了外部相对标准偏差<0.5%和0.7%(1个标准偏差)。基于统计分析,ICP-MS分析得到的铁同位素比率与TIMS得到的比率没有差异,计算出的铁吸收值也没有差异。通过TIMS或ICP-MS测量时,铁吸收的平均值和标准偏差没有差异。2微升的红细胞样本足以进行ICP-MS铁同位素比率分析,内部相对标准偏差<0.5%,分析时间<5分钟。这项技术可能有助于各研究团队增加使用稳定同位素方法来评估婴幼儿的铁吸收情况。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验