38例踝关节骨折合并下胫腓联合损伤患者下胫腓联合固定的随机研究:金属螺钉与可吸收螺钉对比

Fixation of syndesmotic ruptures in 38 patients with a malleolar fracture: a randomized study comparing a metallic and a bioabsorbable screw.

作者信息

Kaukonen Juha-Pekka, Lamberg Tommi, Korkala Olli, Pajarinen Jarkko

机构信息

Päijät-Häme Central Hospital, Lahti, Finland.

出版信息

J Orthop Trauma. 2005 Jul;19(6):392-5. doi: 10.1097/01.bot.0000155313.50627.f6.

Abstract

OBJECTIVES

To compare the performance of a metallic and a biodegradable screw in the fixation of tibia-fibula syndesmotic ruptures.

DESIGN

A randomized, prospective, and blinded study.

SETTING

Central hospital, Department of Surgery.

PATIENTS

Forty consecutive patients with a clinically verified syndesmotic rupture in association with a malleolar fracture, of whom 38 completed the study.

INTERVENTION

After syndesmosis rupture was diagnosed, implant selection was performed intraoperatively by a strict randomization with sealed envelopes. Eighteen patients were treated with a metallic screw, and 20 with a bioabsorbable polylevolactic acid screw. The metallic screws were removed in a second operation at 8 weeks postoperatively. All patients had a treatment-blinded clinical and radiographic control after a mean follow-up of 35 (range 17-51) months.

MAIN OUTCOME MEASURES

Return to previous physical activity level, evaluation of ankle stability, range of motion, circumference of the ankle, and a radiographic evaluation of both ankles including a measure of the talocrural, medial joint, and syndesmotic space widths.

RESULTS

More patients with a polylevolactic acid screw returned to their previous activity level, and there was less swelling in the ankles of these patients, but joint motion was similar between the groups. The mean values of syndesmotic and medial joint spaces were significantly higher in the radiographs of the operated ankles when compared to the uninjured ankle, but there was not a correlation to the type of screw used.

CONCLUSIONS

Polylevolactic acid screws worked as well, or slightly better than, metallic ones in syndesmosis fixation in patients with an ankle fracture.

摘要

目的

比较金属螺钉和可生物降解螺钉在固定胫腓下联合韧带断裂中的性能。

设计

一项随机、前瞻性、双盲研究。

地点

中心医院外科。

患者

连续40例经临床证实伴有踝关节骨折的下胫腓联合韧带断裂患者,其中38例完成研究。

干预

诊断下胫腓联合韧带断裂后,术中通过密封信封严格随机化进行植入物选择。18例患者用金属螺钉治疗,20例用生物可吸收聚乳酸螺钉治疗。金属螺钉在术后8周的二次手术中取出。所有患者在平均随访35(范围17 - 51)个月后进行了盲法临床和影像学检查。

主要观察指标

恢复到之前的身体活动水平、踝关节稳定性评估、活动范围、踝关节周长,以及对双踝关节进行影像学评估,包括测量胫距关节、内侧关节和下胫腓联合间隙宽度。

结果

使用聚乳酸螺钉的患者更多恢复到了之前的活动水平,且这些患者的踝关节肿胀较轻,但两组间关节活动情况相似。与未受伤的踝关节相比,手术侧踝关节X线片中下胫腓联合和内侧关节间隙的平均值显著更高,但与所使用螺钉的类型无关。

结论

在踝关节骨折患者的下胫腓联合固定中,聚乳酸螺钉的效果与金属螺钉相当,或略优于金属螺钉。