椎间盘的血流相关力学:体外模型的有效性

Flow-related mechanics of the intervertebral disc: the validity of an in vitro model.

作者信息

van der Veen Albert J, Mullender Margriet, Smit Theo H, Kingma Idsart, van Dieën Jaap H

机构信息

Department of Physics and Medical Technology, VU University Medical Center, Amsterdam, The Netherlands.

出版信息

Spine (Phila Pa 1976). 2005 Sep 15;30(18):E534-9. doi: 10.1097/01.brs.0000179306.40309.3a.

Abstract

STUDY DESIGN

An in vitro mechanical study on porcine motion segments.

OBJECTIVES

To test the validity of in vitro studies of the flow-related mechanics of the intervertebral disc and, in particular, to investigate whether fluid flows back into the disc during unloading after a loading cycle.

SUMMARY OF BACKGROUND DATA

In vivo studies show both the inflow and outflow of fluid in the intervertebral disc. The resistance to flow out of the disc is higher than to inflow. The fluid flow is regulated via unbalance between the external load and the osmotic pressure of the nucleus pulposus.

MATERIALS

There were 8 porcine lumbar motion segments (without posterior elements) and 8 isolated discs tested in a physiologic saline bath (39 degrees C). The specimens were preloaded at 0.025 MPa for 15 minutes. Three 15-minute loading periods at 2.0 MPa were applied, each followed by an unloading period of 30 minutes. Loads, axial displacements, and nucleus pressure were recorded online.

RESULTS

Over the 3 loading and unloading periods, all specimens showed a net loss of height and mass. The time series of specimen height during the 3 unloading periods showed virtually identical responses. The pressure in the nucleus decreased in the subsequent loading periods and showed no increase during unloading.

CONCLUSION

The data show the limitations of an in vitro model for studying fluid flow-related intervertebral disc mechanics. During loading, outflow of fluid occurred, but inflow appears to be virtually absent during unloading. Poro-elastic behavior cannot be reproduced in an in vitro model.

摘要

研究设计

对猪运动节段进行的体外力学研究。

目的

检验椎间盘流体相关力学体外研究的有效性,尤其是研究在加载循环后的卸载过程中,液体是否会回流到椎间盘中。

背景数据总结

体内研究表明椎间盘中存在液体的流入和流出。椎间盘的流出阻力高于流入阻力。液体流动通过外部负荷与髓核渗透压之间的不平衡来调节。

材料

在39摄氏度的生理盐水中测试了8个猪腰椎运动节段(无后部结构)和8个分离的椎间盘。标本在0.025兆帕的预负荷下加载15分钟。施加三个2.0兆帕的15分钟加载期,每个加载期后接着30分钟的卸载期。在线记录负荷、轴向位移和髓核压力。

结果

在三个加载和卸载期内,所有标本的高度和质量均出现净损失。三个卸载期内标本高度的时间序列显示出几乎相同的反应。髓核压力在随后的加载期下降,在卸载期没有增加。

结论

数据显示了用于研究与流体流动相关的椎间盘力学的体外模型的局限性。在加载过程中,液体流出,但在卸载过程中几乎没有流入。体外模型无法再现孔隙弹性行为。