Yoshinobu T, Iwasaki H, Ui Y, Furuichi K, Ermolenko Yu, Mourzina Yu, Wagner T, Näther N, Schöning M J
The Institute of Scientific and Industrial Research, Osaka University, 8-1 Mihogaoka, Ibaraki, Osaka 567-0047, Japan.
Methods. 2005 Sep;37(1):94-102. doi: 10.1016/j.ymeth.2005.05.020. Epub 2005 Sep 30.
The light-addressable potentiometric sensor (LAPS) is a semiconductor-based chemical sensor with an electrolyte-insulator-semiconductor structure. The LAPS can have many measuring points integrated on the sensing surface, which are individually accessed by a light beam. By modifying the measuring points with different materials, a single sensor plate can be used as a multi-analyte sensor. In this paper, instrumentation and application of LAPS to multi-ion sensing and imaging are described. As a new application of LAPS, potentiometric imaging of a microfluidic channel is proposed.
光寻址电位传感器(LAPS)是一种基于半导体的化学传感器,具有电解质-绝缘体-半导体结构。LAPS可以在传感表面集成多个测量点,这些测量点可通过光束单独访问。通过用不同材料修饰测量点,单个传感器板可以用作多分析物传感器。本文描述了LAPS在多离子传感和成像方面的仪器和应用。作为LAPS的一种新应用,提出了微流控通道的电位成像。