Suppr超能文献

电子中子个人剂量计:它们在核电站混合辐射场中的性能。

Electronic neutron personal dosemeters: their performance in mixed radiation fields in nuclear power plants.

作者信息

Luszik-Bhadra M, Bartlett D, Boschung M, Coeck M, Curzio G, Derdau D, d'Errico F, Fiechtner A, Itié C, Kyllönen J-E, Lacoste V, Lahaye T, Lindborg L, Molinos C, Reginatto M, Schuhmacher H, Tanner R, Vanhavere F

机构信息

Physikalisch-Technische Bundesanstalt, D-38116 Braunschweig, Germany.

出版信息

Radiat Prot Dosimetry. 2006;120(1-4):378-82. doi: 10.1093/rpd/nci556. Epub 2006 Apr 27.

Abstract

This work describes spectral distributions of neutrons obtained as function of energy and direction at four workplace fields at the Krümmel reactor in Germany. Values of personal dose equivalent H(p)(10) and effective dose E are determined for different directions of a person's orientation in these fields and readings of personal neutron dosemeters--especially electronic dosemeters--are discussed with respect to H(p)(10) and E.

摘要

这项工作描述了在德国Krümmel反应堆的四个工作场所获得的中子能谱分布,该能谱分布是能量和方向的函数。针对人员在这些场所中不同的朝向,确定了个人剂量当量H(p)(10)和有效剂量E的值,并就H(p)(10)和E讨论了个人中子剂量计(尤其是电子剂量计)的读数。