Suppr超能文献

泰瑟枪致眼部穿通伤

Perforating ocular injury by Taser.

作者信息

Chen Sandy L, Richard Christen K, Murthy Raghu C, Lauer Andreas K

出版信息

Clin Exp Ophthalmol. 2006 May-Jun;34(4):378-80. doi: 10.1111/j.1442-9071.2006.01228.x.

Abstract

This report describes the features, treatment and outcome of globe perforation by a Taser dart electrode in a 21-year-old man. The Taser electrode caused mechanical iris, lens and retinal injury and consequent retinal detachment as result of proliferative vitreoretinopathy. The effect of electrical stimulation on ocular tissues is unknown. After the scleral and corneal wounds, traumatic cataract and retinal tear were repaired, the patient regained a visual acuity of 6/18. Nine months later a retinal detachment with proliferative vitreoretinopathy was discovered. The Taser may cause globe perforation and posterior segment injury. Understanding the barbed configuration of the dart electrode is important when extricating this device. Visual recovery is possible despite electric discharge of the Taser and suggests that the mechanism of ocular injury is largely mechanical.

摘要

本报告描述了一名21岁男性被泰瑟枪飞镖电极导致眼球穿孔的特征、治疗及结果。泰瑟枪电极造成了机械性虹膜、晶状体和视网膜损伤,以及因增殖性玻璃体视网膜病变导致的视网膜脱离。电刺激对眼组织的影响尚不清楚。在修复巩膜和角膜伤口、外伤性白内障和视网膜裂孔后,患者视力恢复至6/18。九个月后发现伴有增殖性玻璃体视网膜病变的视网膜脱离。泰瑟枪可能导致眼球穿孔和眼后段损伤。取出该装置时,了解飞镖电极的带刺结构很重要。尽管泰瑟枪放电,但视力仍有可能恢复,这表明眼损伤机制主要是机械性的。