Suppr超能文献

Vacuum sampling techniques for industrial hygienists, with emphasis on beryllium dust sampling.

作者信息

Creek Kathryn L, Whitney Gary, Ashley Kevin

机构信息

Los Alamos National Laboratory, P.O. Box 1663, M.S. D454, Bikini Atoll Road, SM-30, Los Alamos, NM 87545, USA.

出版信息

J Environ Monit. 2006 Jun;8(6):612-8. doi: 10.1039/b601572g. Epub 2006 May 25.

Abstract

The U.S. Department of Energy (DOE) Chronic Beryllium Disease Prevention Program Rule, 10 CFR Part 850 became effective in 2000 in response to the prevalence of Chronic Beryllium Disease (CBD) in workers. The rule requires surface and air monitoring for beryllium to determine exposure levels and the evaluation of the effectiveness of controls used to minimize or eliminate that risk. The most common methods for surface sampling use wet or dry wipes. Wipe sampling techniques may be impractical for many surfaces common to most buildings such as cinder block, textured wall surfaces, fabric and carpet. Vacuum sampling methods have been developed for the evaluation of lead or pesticides on residential surfaces such as carpets, bare floors and window sills. However, the current vacuum methods may be impractical for many workplace situations such as sampling of protective clothing, complex facility structures, or equipment surfaces. Recent work using vacuum sampling for potential bio-terrorism agents such as anthrax spores may have significant application to industrial hygiene evaluations of the workplace and may be extendable for use in sampling of metals such as beryllium. Validated vacuum sampling methods that provide meaningful data would be of great value to industrial hygienists in identifying areas having surface contamination, evaluating existing controls and work practices and determining the potential of toxic material on surfaces to become airborne and present a potential risk to workers and the public. This article discusses various vacuum sampling methodologies and recommends harmonization of sampling methods.

摘要

相似文献

1
Vacuum sampling techniques for industrial hygienists, with emphasis on beryllium dust sampling.
J Environ Monit. 2006 Jun;8(6):612-8. doi: 10.1039/b601572g. Epub 2006 May 25.
2
Field evaluation and comparison of five methods of sampling lead dust on carpets.
AIHA J (Fairfax, Va). 2003 Jul-Aug;64(4):528-32. doi: 10.1202/1542-8125(2003)64(528:FEACOF)2.0.CO;2.
3
Beryllium Exposure Control Program at the Cardiff Atomic Weapons Establishment in the United Kingdom.
Appl Occup Environ Hyg. 2001 May;16(5):619-30. doi: 10.1080/10473220118634.
4
Evaluation of a standardized micro-vacuum sampling method for collection of surface dust.
J Occup Environ Hyg. 2007 Mar;4(3):215-23. doi: 10.1080/15459620601177461.
5
Exposure pathway assessment at a copper-beryllium alloy facility.
Ann Occup Hyg. 2007 Jan;51(1):67-80. doi: 10.1093/annhyg/mel041. Epub 2006 Jul 14.
7
Efficacy of surface sampling methods for different types of beryllium compounds.
J Environ Monit. 2011 Jan;13(1):74-83. doi: 10.1039/c001105c. Epub 2010 Oct 28.
8
Cleaning efficacy of high-efficiency particulate air-filtered vacuuming and "dry steam" cleaning on carpet.
J Occup Environ Hyg. 2008 Feb;5(2):94-9. doi: 10.1080/15459620701805169.

引用本文的文献

1
Optical molecular fluorescence determination of ultra-trace beryllium in occupational and environmental samples using highly alkaline conditions.
Int J Environ Anal Chem. 2017;97(3):264-275. doi: 10.1080/03067319.2017.1302582. Epub 2017 Mar 14.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验