Gao Min-guang, Liu Wen-qing, Zhang Tian-shu, Liu Cheng, Liu Jian-guo, Wei Qing-nong, Lu Yi-huai, Wang Ya-ping, Zhu Jun, Xu Liang
Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China.
Guang Pu Xue Yu Guang Pu Fen Xi. 2006 Jan;26(1):47-50.
The principle and techniques of passive remote sensing of gaseous pollutant in heated plume was illustrated and discussed in this paper. The algorithm of radiance spectra and transmittance spectra in measured region was proposed, and the method of retrieving gas concentrations with NLLS fitting algorithm was also proposed. The remote senseing of actual gaseous pollutant of smokestack was done, and the quantitative analysis of SO2 and CO2 was completed.
本文阐述并讨论了热羽流中气态污染物被动遥感的原理和技术。提出了测量区域辐射光谱和透过率光谱的算法,并提出了用非线性最小二乘拟合算法反演气体浓度的方法。对烟囱实际气态污染物进行了遥感测量,并完成了对SO₂和CO₂的定量分析。