Suppr超能文献

后牙无金属聚合物冠的临床磨损情况。一项随机临床试验的一年结果。

Clinical wear of posterior metal-free polymer crowns. One-year results from a randomized clinical trial.

作者信息

Ohlmann Brigitte, Uekermann Jan, Dreyhaupt Jens, Schmitter Marc, Mussotter Katrin, Rammelsberg Peter

机构信息

Department of Prosthodontics, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany.

出版信息

J Dent. 2007 Mar;35(3):246-52. doi: 10.1016/j.jdent.2006.09.001. Epub 2006 Oct 5.

Abstract

OBJECTIVES

The purpose of this randomized clinical trial was to evaluate the clinical wear behavior of posterior, metal-free polymer crowns, with and without a glass-fiber framework, and to compare it with that of metal-ceramic crowns.

METHODS

Eighty single crowns manufactured from a newly designed polymer composite were set in posterior teeth. Half of these received a glass-fiber framework (group 1) whereas half were prepared without framework stabilization (group 2). All polymer crowns were adhesively luted with resin cement. As the control group, 40 conventional metal-ceramic crowns were inserted with hybrid cement. Wear was measured, by use of gypsum replicas, at baseline and after 12 months, by use of a 3D laser scanner. Statistical analysis was performed using mixed-effects regression model analyses.

RESULTS

The mean total wear of posterior single crowns was -8.1 microm (+/-9.7 microm) in group 1, -7.0 microm (+/-9.1 microm) in group 2, and -3.4 microm (+/-6.3 microm) in the control group. Statistical analysis revealed wear behavior was significantly different from the control group for group 1 (p=0.014) and group 2 (p<0.01). No significant difference was detected between groups 1 and 2. Age, gender, and opposing teeth had no significant effect on wear behavior.

CONCLUSIONS

Within a 12-month observation period mean total wear of posterior polymer crowns with and without a glass-fiber framework was significantly greater than for metal-ceramic crowns. The selection of restorative materials should be based on knowledge of clinical wear in order to preserve occlusal stability.

摘要

目的

本随机临床试验旨在评估有无玻璃纤维支架的后部无金属聚合物冠的临床磨损情况,并与金属陶瓷冠进行比较。

方法

用新设计的聚合物复合材料制作80个单冠,安装在后牙上。其中一半安装玻璃纤维支架(第1组),另一半未进行支架固定(第2组)。所有聚合物冠均用树脂粘结剂粘结。作为对照组,40个传统金属陶瓷冠用混合粘结剂进行安装。在基线和12个月后,使用3D激光扫描仪通过石膏模型测量磨损情况。使用混合效应回归模型分析进行统计分析。

结果

第1组后牙单冠的平均总磨损为-8.1微米(±9.7微米),第2组为-7.0微米(±9.1微米),对照组为-3.4微米(±6.3微米)。统计分析显示,第1组(p=0.014)和第2组(p<0.01)的磨损情况与对照组有显著差异。第1组和第2组之间未检测到显著差异。年龄、性别和对颌牙对磨损情况无显著影响。

结论

在12个月的观察期内,有无玻璃纤维支架的后部聚合物冠的平均总磨损明显大于金属陶瓷冠。修复材料的选择应基于对临床磨损的了解,以保持咬合稳定性。