Moore Christopher D, Newman Robert C, Caridi James G
Rev Urol. 2006 Summer;8(3):165-8.
Gadolinium-enhanced magnetic resonance imaging is a diagnostic modality widely used in urologic practice. We report on a 54-year-old woman in whom a critically low serum calcium level was measured with standard colorimetric assay after gadodiamide-enhanced magnetic resonance imaging. The same phenomenon was noted in 2 other patients seen in our practice. Repeat serum calcium measurements performed several hours later were within normal limits. Commercially available gadolinium-based contrast agents might precipitate critically low serum calcium values when measured by standard colorimetric assay. Physician awareness of gadodiamide-induced spurious hypocalcemia might prevent unnecessary therapeutic interventions.
钆增强磁共振成像是泌尿外科实践中广泛使用的一种诊断方式。我们报告了一名54岁女性,在钆双胺增强磁共振成像后,用标准比色法测得其血清钙水平极低。在我们诊所接诊的另外2名患者中也发现了同样的现象。数小时后重复进行的血清钙测量结果在正常范围内。市售的钆基造影剂在用标准比色法测量时可能会导致血清钙值极低。医生了解钆双胺引起的假性低钙血症可能会避免不必要的治疗干预。