Kalva Sanjeeva P, Wicky Stephan
Department of Radiology, Massachusetts General Hospital, Boston and Harvard Medical School, Boston, MA 02114, USA.
Catheter Cardiovasc Interv. 2006 Dec;68(6):858-61. doi: 10.1002/ccd.20902.
We report two patients with cystic fibrosis and mediastinal bronchial artery aneurysms treated by means of endovascular coil embolization. In one case, the presence of a long segment of bronchial artery proximal to the aneurysm allowed coil embolization with regular steel coils. In the second case, the aneurysm was near the origin of the bronchial artery from the aorta. We used detachable coils to occlude this aneurysm for more precise embolization.
我们报告了两例患有囊性纤维化并伴有纵隔支气管动脉瘤的患者,他们接受了血管内弹簧圈栓塞治疗。在一例中,动脉瘤近端存在一段较长的支气管动脉,这使得可以使用普通钢圈进行弹簧圈栓塞。在另一例中,动脉瘤靠近支气管动脉从主动脉发出的起始处。我们使用可脱卸弹簧圈来闭塞该动脉瘤,以实现更精确的栓塞。