Suppr超能文献

A novel approach to flexor hallucis longus tenography.

作者信息

Gelbart Michael S, Parikh Ashesh, Chong Wincha, Gilula Louis A

机构信息

Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 S. Kingshighway Blvd., St. Louis, MO 63110, USA.

出版信息

AJR Am J Roentgenol. 2006 Dec;187(6):1432-5. doi: 10.2214/AJR.05.0345.

Abstract

OBJECTIVE

This article presents a technically simple and more accurate approach to flexor hallucis longus (FHL) tenography than any we found reported in the literature.

CONCLUSION

Tenography is used to evaluate and treat tenosynovitis. Standard FHL tenography protocol involves either direct percutaneous access of the FHL synovial sheath posterior to the medial malleolus or indirect filling of the FHL sheath from an injection of the flexor digitorum longus (FDL) tendon sheath, which often communicates with the FHL tendon sheath. However, with these methods, difficulty entering the FHL sheath may be encountered. We adapted our technique to access the FHL sheath as it courses below the sustentaculum talus. Our early experience with five cases using this technique reflects a 100% success rate with accurate needle placement within the FHL tendon sheath, thereby improving procedural efficiency.