Imoto Kenshi, Takebayashi Tsuneo, Kanaya Kunihito, Kawaguchi Satoshi, Katahira Genichirou, Yamashita Toshihiko
Department of Orthopaedic Surgery, School of Medicine, Sapporo Medical University, Sapporo 060-8543, Japan.
Eur Spine J. 2007 Jul;16(7):971-5. doi: 10.1007/s00586-006-0285-7. Epub 2007 Jan 3.
A Neurometer device is an electrical nerve stimulator used to determine the current perception threshold (CPT) evoked by stimulating A-beta fibers at 2,000 Hz, A-delta fibers at 250 Hz and C fibers at 5 Hz. CPT evaluation is used for analyzing peripheral nerve dysfunction. In this study, the sensory disturbance of the lower-extremity was quantitatively analyzed using CPT testing before and after lumbar discectomy. In 33 patients (L4/5: 16 and L5/S: 17), as subjective evaluations, tactile sensation and leg pain were assessed before and 2 weeks after surgery. In the subjectively improved group (n = 22), significant decreases in CPT at 2,000 and 250 Hz were noted postoperatively, whereas in the unchanged group (n = 11), no significant changes in CPT at any frequencies was noted. The leg pain improved in all patients. Likewise, CPT at 5 Hz, which stimulated C fiber, decreased significantly for both improved and unchanged groups. CPT measured by a Neurometer is very useful in assessing lower-extremity sensory functions before and after surgery for lumbar disc herniation.
神经测量仪是一种电神经刺激器,用于确定以2000赫兹刺激Aβ纤维、以250赫兹刺激Aδ纤维以及以5赫兹刺激C纤维时诱发的电流感觉阈值(CPT)。CPT评估用于分析周围神经功能障碍。在本研究中,通过腰椎间盘切除术前和术后的CPT测试对下肢的感觉障碍进行了定量分析。在33例患者(L4/5:16例,L5/S:17例)中,作为主观评估,在手术前和术后2周评估触觉和腿痛。在主观改善组(n = 22)中,术后2000赫兹和250赫兹时的CPT显著降低,而在未改变组(n = 11)中,任何频率的CPT均无显著变化。所有患者的腿痛均有所改善。同样,刺激C纤维的5赫兹时的CPT在改善组和未改变组中均显著降低。通过神经测量仪测量的CPT在评估腰椎间盘突出症手术前后的下肢感觉功能方面非常有用。