Suppr超能文献

聚四氟乙烯/聚丙交酯-乙交酯层压材料中缓释曲尼司特可延迟兔斜视手术后的调整。

Slow-releasing tranilast in polytetrafluoroethylene/polylactide-co-glycolide laminate delays adjustment after strabismus surgery in rabbit model.

作者信息

Lee Min Joung, Jin Su-Eon, Kim Chong-Kook, Choung Ho-Kyung, Jeoung Jin Wook, Kim Hwa Jung, Choe Gheeyoung, Hwang Jeong-Min

机构信息

Department of Ophthalmology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Korea.

出版信息

Invest Ophthalmol Vis Sci. 2007 Feb;48(2):699-704. doi: 10.1167/iovs.06-0775.

Abstract

PURPOSE

To determine the usefulness of slow-releasing tranilast in polytetrafluoroethylene/polylactide-co-glycolide (PTFE/PLGA) laminate for delayed adjustable strabismus surgery.

METHODS

A prospective, masked-observer, controlled study was performed in 25 rabbits. Fifty rabbit eyes were divided randomly into three groups. After a recession of the superior rectus muscle (SRM), a PTFE/PLGA laminate containing tranilast, PTFE alone, or balanced salt solution was applied beneath and over the SRM in the PTFE/PLGA-tranilast group (group P-T), the PTFE group (group P), and the control group, respectively. Delayed adjustment was performed by a masked observer once on each SRM 3 or 5 weeks after surgery. Adjustability, adjustment lengths, forces required, and adhesion degrees were evaluated.

RESULTS

In the control group, adjustment was impossible in any eye 3 or 5 weeks after surgery. In group P, adjustment was possible in 5 of 8 eyes 3 weeks after surgery and in 5 of 10 eyes 5 weeks after surgery. In group P-T, adjustment was possible in 8 of 10 eyes 3 and 5 weeks after surgery. On comparing adjustability, a significant difference was observed between group P-T and the control group 3 and 5 weeks after surgery (P = 0.006, P = 0.006, respectively). A significant difference was observed between group P-T and the control group (P = 0.016) in terms of adhesion between SRMs and conjunctivae 5 weeks after surgery.

CONCLUSIONS

Slow-releasing tranilast in PTFE/PLGA was found to reduce adhesion and allowed delayed adjustment in most eyes for up to 5 weeks after surgery.

摘要

目的

确定缓释曲尼司特在聚四氟乙烯/聚乳酸-共-乙醇酸(PTFE/PLGA)层压板中用于延迟可调斜视手术的有效性。

方法

对25只兔子进行了一项前瞻性、盲法观察的对照研究。将50只兔眼随机分为三组。在进行上直肌(SRM)后徙术后,分别在PTFE/PLGA-曲尼司特组(P-T组)、PTFE组(P组)和对照组的SRM下方和上方应用含曲尼司特的PTFE/PLGA层压板、单独的PTFE或平衡盐溶液。术后3周或5周,由盲法观察者对每只SRM进行一次延迟调整。评估可调性、调整长度、所需力量和粘连程度。

结果

对照组在术后3周或5周,任何一只眼睛都无法进行调整。P组在术后3周,8只眼中有5只可进行调整;术后5周,10只眼中有5只可进行调整。P-T组在术后3周和5周,10只眼中有8只可进行调整。比较可调性发现,术后3周和5周,P-T组与对照组之间存在显著差异(分别为P = 0.006,P = 0.006)。术后5周,SRM与结膜之间的粘连情况,P-T组与对照组之间存在显著差异(P = 0.016)。

结论

发现PTFE/PLGA中的缓释曲尼司特可减少粘连,并使大多数眼睛在术后长达5周内能够进行延迟调整。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验