Technical note: compatibility of microtomographic imaging systems for dental measurements.

作者信息

Olejniczak Anthony J, Tafforeau Paul, Smith Tanya M, Temming Heiko, Hublin Jean-Jacques

机构信息

Department of Human Evolution, Max Planck Institute for Evolutionary Anthropology, Deutscher Platz 6, D-04103 Leipzig, Germany.

出版信息

Am J Phys Anthropol. 2007 Sep;134(1):130-4. doi: 10.1002/ajpa.20615.

Abstract

Modern micro-computed tomography techniques allow the accurate visualization of internal dental structures, and are becoming widely used within (paleo-) anthropological dental studies. There exist several types and name brands of microtomographic systems, however, which have been demonstrated to produce images that vary in resolution and signal-to-noise ratio. As a growing body of dental research using disparate microtomographic techniques is likely to continue accumulating, it is imperative that different systems are compared to ensure that results are comparable and not machine-dependent. In the present study, we compare volume, surface area, and linear measurements recorded on a sample of modern and fossil teeth using four microtomographic systems (three laboratory scanners, and the ID19 beamline of the European Synchrotron Radiation Facility). Results indicate that measurements are comparable between systems (within 3%), but that synchrotron radiation is superior to the other systems because its monochromatic X-rays prevent beam hardening and its parallel beam prevents geometric artifacts in the resultant images, making it easier to record measurements and see fine details at the enamel cervix or dentine horn tips. Although the synchrotron produces higher resolution images with less artifacts, results indicate that for gross morphological measurements (e.g., enamel cap volume, intercuspal distances), each of the scanners produces approximately the same measurements. Combining measurements of teeth from multiple microCT systems presupposes that measurements from each system are comparable; the research presented here indicates that this is the case when teeth are not severely diagenetically remineralized.

摘要

现代微计算机断层扫描技术能够精确呈现牙齿内部结构,在(古)人类学牙齿研究中得到广泛应用。然而,微断层扫描系统有多种类型和品牌,其产生的图像在分辨率和信噪比方面存在差异。随着使用不同微断层扫描技术的牙齿研究不断增加,必须对不同系统进行比较,以确保结果具有可比性且不依赖于机器。在本研究中,我们使用四种微断层扫描系统(三台实验室扫描仪以及欧洲同步辐射装置的ID19光束线),对现代和化石牙齿样本的体积、表面积和线性测量值进行了比较。结果表明,各系统之间的测量结果具有可比性(误差在3%以内),但同步辐射优于其他系统,因为其单色X射线可防止束硬化,平行光束可防止所得图像中出现几何伪影,从而更便于记录测量值并看清釉质颈或牙本质角尖端的细微细节。尽管同步辐射产生的图像分辨率更高且伪影更少,但结果表明,对于总体形态测量(如釉帽体积、牙尖间距离),每种扫描仪的测量结果大致相同。将来自多个微CT系统的牙齿测量结果相结合,前提是每个系统的测量结果具有可比性;此处的研究表明,当牙齿没有严重的成岩再矿化时,情况确实如此。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验