Suppr超能文献

[乳腺三维/四维容积超声的现状]

[Current status of 3D/4D volume ultrasound of the breast].

作者信息

Weismann C, Hergan K

机构信息

Department für Mammadiagnostik und Mammaintervention, Universitätsinstitut für Radiodiagnostik, LKH Salzburg.

出版信息

Ultraschall Med. 2007 Jun;28(3):273-82. doi: 10.1055/s-2007-963225.

Abstract

3D/4D volume ultrasound is an established method that offers various options for analyzing and presenting ultrasound volume data. The following imaging techniques are based on automatically acquired ultrasound volumes. The multiplanar view is the typical mode of 3D ultrasound data presentation. The niche mode view is a cut open view of the volume data set. The surface mode is a rendering technique that represents the data within a volume of interest (VOI) with different slice thicknesses (typically 1-4 mm) with a contrast-enhanced surface algorithm. Related to the diagnostic target, the transparency mode helps to present echopoor or echorich structures and their spatial relationships within the ultrasound volume. Glass body rendering is a special type of transparency mode that makes the grayscale data transparent and shows the color flow data in a surface render mode. The inversion mode offers a three-dimensional surface presentation of echopoor lesions. Volume Contrast Imaging (VCI) works with static 3D volume data and is able to be used with 4D for dynamic scanning. Volume calculation of a lesion and virtual computer-assisted organ analysis of the same lesion is performed with VoCal software. Tomographic Ultrasound Imaging (TUI) is the perfect tool to document static 3D ultrasound volumes. 3D/4D volume ultrasound of the breast provides diagnostic information of the coronal plane. In this plane benign lesions show the compression pattern sign, while malignant lesions show the retraction pattern or star pattern sign. The indeterminate pattern of a lesion combines signs of compression and retraction or star pattern in the coronal plane. Glass body rendering in combination with Power-Doppler, Color-Doppler or High-Definition Flow Imaging presents the intra- and peritumoral three-dimensional vascular architecture. 3D targeting shows correct or incorrect needle placement in all three planes after 2D or 4D needle guidance. In conclusion, it is safe to say that 3D/4D volume ultrasound of the breast is technically advanced and suitable for daily diagnostic and interventional breast work in addition to routinely used 2D sonography.

摘要

三维/四维容积超声是一种成熟的方法,为分析和呈现超声容积数据提供了多种选择。以下成像技术基于自动采集的超声容积。多平面视图是三维超声数据呈现的典型模式。龛模式视图是容积数据集的切开视图。表面模式是一种渲染技术,它使用对比度增强表面算法,以不同的切片厚度(通常为1 - 4毫米)表示感兴趣容积(VOI)内的数据。与诊断目标相关,透明模式有助于呈现超声容积内回声低或回声高的结构及其空间关系。玻璃体渲染是一种特殊类型的透明模式,它使灰度数据透明,并以表面渲染模式显示彩色血流数据。反转模式提供了回声低病变的三维表面呈现。容积对比成像(VCI)处理静态三维容积数据,并且能够与四维一起用于动态扫描。使用VoCal软件对病变进行容积计算以及对同一病变进行虚拟计算机辅助器官分析。断层超声成像(TUI)是记录静态三维超声容积的理想工具。乳腺的三维/四维容积超声提供冠状面的诊断信息。在这个平面上,良性病变显示压迫模式征,而恶性病变显示回缩模式或星状模式征。病变的不确定模式在冠状面结合了压迫和回缩或星状模式的征象。玻璃体渲染与能量多普勒、彩色多普勒或高清血流成像相结合,呈现肿瘤内和肿瘤周围的三维血管结构。在二维或四维针引导后,三维靶向显示针在所有三个平面中的放置正确与否。总之,可以肯定地说,乳腺的三维/四维容积超声技术先进,除了常规使用的二维超声检查外,还适用于日常乳腺诊断和介入工作。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验