Suppr超能文献

使用平面pH电极评估生石灰掺入实验室规模和全规模石灰稳定生物固体中的情况。

Evaluation of quicklime incorporation in bench-scale and full-scale lime stabilized biosolids using a flat surface pH electrode.

作者信息

Burns Benjamin, Krach Kenneth, Cole Charles, Mangus Jessica, Butler Howard, Li Baikun

机构信息

Environmental Engineering Program, Pennsylvania State University at Harrisburg, Middletown, PA, USA.

出版信息

J Air Waste Manag Assoc. 2007 Jul;57(7):794-802. doi: 10.1080/1047-3289.57.7.794.

Abstract

Uniform lime incorporation into sewage sludge is critical for biosolid lime stabilization processes. There is no class B biosolids regulation for lime incorporation. The slurry method is currently used to evaluate the pH of limed biosolids, but this method homogenizes the biosolids and potentially masks poor lime mixing. In this study, a flat-surface pH electrode was used in bench-scale and full-scale experiments to measure the pH of lime-stabilized biosolids without creating slurries. The standard deviation of 15 pH measurements at different locations in a biosolid sample was used to assess mixing quality. The bench-scale experimental study showed that well-mixed limed biosolids had consistently high pHs (approximately 12) with low standard deviations (< 0.5 pH units), whereas poorly mixed biosolids had areas with low pH (< 10) and high standard deviations (> 2 pH units). Poorly mixed biosolids exhibited rapid and marked pH reduction, as well as offensive odor generation, whereas well-mixed biosolids resisted pH reduction and offensive odor generation. The full-scale study aimed at improving lime incorporation and biosolids quality confirmed the use of a flat surface pH electrode to capture low pH regions in biosolids that were masked by the current slurry method.

摘要

将石灰均匀掺入污水污泥中对于生物固体石灰稳定化过程至关重要。目前没有关于石灰掺入的B级生物固体法规。目前使用浆液法来评估加石灰生物固体的pH值,但这种方法会使生物固体均匀化,并可能掩盖石灰混合不佳的情况。在本研究中,在实验室规模和全规模实验中使用平面pH电极来测量石灰稳定化生物固体的pH值,而无需制成浆液。使用生物固体样品中不同位置的15次pH测量的标准偏差来评估混合质量。实验室规模的实验研究表明,充分混合的加石灰生物固体具有始终较高的pH值(约为12)且标准偏差较低(<0.5个pH单位),而混合不佳的生物固体存在低pH值区域(<10)且标准偏差较高(>2个pH单位)。混合不佳的生物固体表现出pH值迅速且显著降低,以及产生难闻气味,而充分混合的生物固体则能抵抗pH值降低和难闻气味的产生。旨在改善石灰掺入和生物固体质量的全规模研究证实了使用平面pH电极来捕捉被当前浆液法掩盖的生物固体中的低pH值区域。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验