Suppr超能文献

全膝关节置换术中胫骨部件的固定:带栓和带柄设计的比较。

Tibial component fixation in total knee arthroplasty: a comparison of pegged and stemmed designs.

作者信息

Bertin Kim C

机构信息

Utah Hip and Knee Center, Salt Lake City, Utah, USA.

出版信息

J Arthroplasty. 2007 Aug;22(5):670-8. doi: 10.1016/j.arth.2006.07.004. Epub 2007 Mar 28.

Abstract

This study compares midterm radiographic, functional, and quality-of-life outcomes in patients receiving a cemented tibial component that has either a short intramedullary stem or one that has a pegged tibial component. A cohort of 181 patients received 225 NexGen cruciate-retaining implants (84 stemmed, 141 pegged) during total knee arthroplasty, with annual follow-up examinations for up to 7 years. Both types of tibial components were associated with excellent radiographic and clinical results with no radiographic evidence of implant loosening or osteolysis. Clinical outcomes included improvement in joint function and patient function, as well as quality of life. Survival analysis showed 98% survival at 7 years with both implants. Pegged tibial components offered comparable midterm radiographic, functional, and quality-of-life results to stemmed components.

摘要

本研究比较了接受带有短髓内柄的骨水泥型胫骨组件或带栓胫骨组件的患者的中期影像学、功能和生活质量结果。181例患者在全膝关节置换术中接受了225枚NexGen保留交叉韧带的植入物(84枚带柄,141枚带栓),并进行了长达7年的年度随访检查。两种类型的胫骨组件均与优异的影像学和临床结果相关,没有植入物松动或骨溶解的影像学证据。临床结果包括关节功能和患者功能的改善以及生活质量的提高。生存分析显示,两种植入物在7年时的生存率均为98%。带栓胫骨组件在中期影像学、功能和生活质量方面的结果与带柄组件相当。