聚丙烯板艾哈迈德青光眼引流阀与硅胶板艾哈迈德青光眼可弯曲引流阀的比较。

A comparison of the polypropylene plate Ahmed glaucoma valve to the silicone plate Ahmed glaucoma flexible valve.

作者信息

Hinkle D M, Zurakowski D, Ayyala R S

机构信息

Department of Ophthalmology, Tulane University Health Sciences Center, New Orleans, LA 70112-2699, USA.

出版信息

Eur J Ophthalmol. 2007 Sep-Oct;17(5):696-701. doi: 10.1177/112067210701700502.

Abstract

PURPOSE

To compare surgical outcomes following implantation of the polypropylene plate Ahmed glaucoma valve (AGV) (S-2) and the newer silicone plate AGV (FP-7) with minimum 12 months follow-up in patients with intractable glaucoma.

DESIGN

Retrospective chart review of 25 eyes of 22 patients who underwent FP-7 and 26 eyes of 22 patients who underwent S-2 AGV implantation by a single surgeon. Main outcome measures included surgical outcomes in terms of intraocular pressure (IOP) control, hypertensive phase, and postoperative complications.

RESULTS

There were no significant differences in diagnoses, pre-and postoperative IOP, pre- and postoperative visual acuities at all time points, and in the number of pre- and postoperative medications between the groups. Significant IOP reductions occurred after FP-7 implantation (29.6 +/- 13.1 to 12.1 +/- 3.4, p < 0.001) and S-2 implantation (31.4 +/- 11.7 to 16.1 +/- 5.7, p < 0.001). The FP-7 group had a statistically lower IOP compared to the S-2 group at 6 (p<0.05), 9 (p<0.01), and 12 months (p<0.01). There was no significant difference in the hypertensive phase between the two groups (p=0.41).

CONCLUSIONS

FP-7 model silicone plate AGV resulted in lower IOP compared to the older S-2 polypropylene plate AGV at 1 year. This may suggest that the plate material may influence clinical outcome.

摘要

目的

比较聚丙烯板Ahmed青光眼引流阀(AGV)(S-2型)和新型硅胶板AGV(FP-7型)植入术后的手术效果,对难治性青光眼患者进行至少12个月的随访。

设计

对22例接受FP-7型植入术患者的25只眼和22例接受S-2型AGV植入术患者的26只眼进行回顾性病历分析,由同一位外科医生实施手术。主要观察指标包括眼压(IOP)控制、高眼压期及术后并发症方面的手术效果。

结果

两组在诊断、术前和术后各时间点的眼压、术前和术后视力以及术前和术后用药数量方面均无显著差异。FP-7型植入术后眼压显著降低(从29.6±13.1降至12.1±3.4,p<0.001),S-2型植入术后眼压也显著降低(从31.4±11.7降至16.1±5.7,p<0.001)。在6个月(p<0.05)、9个月(p<0.01)和12个月(p<0.01)时,FP-7组的眼压在统计学上低于S-2组。两组高眼压期无显著差异(p=0.41)。

结论

与较旧的S-2型聚丙烯板AGV相比,FP-7型硅胶板AGV在1年时眼压更低。这可能表明板材会影响临床效果。