Hoelen C G, de Mul F F, Pongers R, Dekker A
Opt Lett. 1998 Apr 15;23(8):648-50. doi: 10.1364/ol.23.000648.
We applied photoacoustics as a tissue tomography technique for the detection of blood concentrations, e.g., angiogenesis around tumors. We imaged blood vessels in highly scattering samples, using 532-nm light, to depths of ~1 cm . The samples were real tissue (chicken breast) or 10% dilutions of Intralipid-10%. The blood flowed through nylon capillaries. Polyvinylidene difluoride (PVdF) piezoelectric detectors were used in a surface-scanning mode. We demonstrate the sensitivity of the technique by photoacoustic detection of single red blood cells upon a glass plate. Lateral resolution is limited by the detector diameter (200 microm). The depth resolution is ~10 microm.