Suppr超能文献

睾丸体积与睾丸功能之间的关系:不育症患者中普氏睾丸测量法与超声测量法的比较

Relationship between testicular volume and testicular function: comparison of the Prader orchidometric and ultrasonographic measurements in patients with infertility.

作者信息

Sakamoto Hideo, Ogawa Yoshio, Yoshida Hideki

机构信息

Department of Urology, Showa University School of Medicine, 1-5-8 Hatanodai, Shinagawa-ku, Tokyo, Japan.

出版信息

Asian J Androl. 2008 Mar;10(2):319-24. doi: 10.1111/j.1745-7262.2008.00340.x. Epub 2007 Dec 20.

Abstract

AIM

To evaluate the relationship between testicular function and testicular volume measured by using Prader orchidometry and ultrasonography (US) to determine the critical testicular volume indicating normal testicular function by each method.

METHODS

Total testicular volume (right plus left testicular volume) was measured in 794 testes in 397 men with infertility (mean age, 35.6 years) using a Prader orchidometer and also by ultrasonography. Ultrasonographic testicular volumes were calculated as length X width X height X 0.71. To evaluate volume-function relationships, patients were divided into 10 groups representing 5-mL increments of total testicular volume by each method from below 10 mL to 50 mL or more.

RESULTS

Mean total testicular volume based on Prader orchidometry and US were 36.8 mL and 26.3 mL, respectively. Semen volume, sperm density, total sperm count, total motile sperm count, and serum FSH, LH, and testosterone all correlated significantly with total testicular volume measured by either method. Mean sperm density was in the oligozoospermic range in patients with total testicular volume below 35 mL by orchidometry or below 20 mL by ultrasonography. Mean total sperm count was subnormal in patients with total testicular volume below 30 mL by orchidometry or under 20 mL by ultrasonography.

CONCLUSION

Testicular volume measured by either ultrasonography or Prader orchidometry correlated significantly with testicular function. However, critical total testicular volume indicating normal or nearly normal testicular function was 30 mL to 35 mL using Prader orchidometer and 20 mL using ultrasonography. Prader orchidometry morphometrically and functionally overestimated the testicular volume in comparison to US.

摘要

目的

评估睾丸功能与使用普拉德睾丸测量器及超声检查(US)所测睾丸体积之间的关系,以确定每种方法表明睾丸功能正常的临界睾丸体积。

方法

采用普拉德睾丸测量器及超声检查,对397例不育男性(平均年龄35.6岁)的794个睾丸测量其总睾丸体积(右侧加左侧睾丸体积)。超声检查所测睾丸体积通过长度×宽度×高度×0.71计算得出。为评估体积与功能的关系,将患者按每种方法所测总睾丸体积以5毫升递增分为10组,范围从10毫升以下至50毫升及以上。

结果

基于普拉德睾丸测量器及超声检查所测的平均总睾丸体积分别为36.8毫升和26.3毫升。精液量、精子密度、总精子数、总活动精子数以及血清促卵泡激素(FSH)、促黄体生成素(LH)和睾酮均与两种方法所测的总睾丸体积显著相关。通过普拉德睾丸测量器所测总睾丸体积低于35毫升或超声检查低于20毫升的患者,其平均精子密度处于少精子症范围。通过普拉德睾丸测量器所测总睾丸体积低于30毫升或超声检查低于20毫升的患者,其平均总精子数低于正常水平。

结论

超声检查或普拉德睾丸测量器所测睾丸体积与睾丸功能显著相关。然而,使用普拉德睾丸测量器表明睾丸功能正常或接近正常的临界总睾丸体积为30至35毫升,而超声检查为20毫升。与超声检查相比,普拉德睾丸测量器在形态学和功能上高估了睾丸体积。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验