Weller R N, Jurcak J J, Donley D L, Kulild J C
U.S. Army Dental Activity, Fort Gordon, GA.
J Endod. 1991 Oct;17(10):491-4. doi: 10.1016/S0099-2399(06)81796-6.
A new model system was developed which allows intracanal temperature measurements to be recorded during repeated obturations of a human tooth root canal. A human central incisor was embedded in clear orthodontic resin and sectioned longitudinally. Sixteen thermocouples were secured at 2-mm intervals along two surfaces of the root canal. The thermocouples were connected to a computerized temperature recording system to measure intracanal temperatures produced by high-temperature thermoplasticized injectable gutta-percha. The system was capable of recording 16 simultaneous temperatures every second with an accuracy of a hundredth degree centigrade. There was a linear increase in the recorded temperatures in the root canal. However, the actual temperatures were lower than expected.