Suppr超能文献

使用显微拉曼光谱法研究基于树脂的复合材料中未反应的甲基丙烯酸酯基团与样品制备和储存条件的关系。

Remaining unreacted methacrylate groups in resin-based composite with respect to sample preparation and storing conditions using micro-Raman spectroscopy.

作者信息

Miletic Vesna J, Santini Ario

机构信息

Postgraduate Dental Institute, University of Edinburgh, Edinburgh EH3 9HA, United Kingdom.

出版信息

J Biomed Mater Res B Appl Biomater. 2008 Nov;87(2):468-74. doi: 10.1002/jbm.b.31128.

Abstract

The aim of this study was to measure degree of conversion (DC) of resin-based composites (RBCs) using micro-Raman spectroscopy followed by different sample preparation procedures and storing conditions. Ninety samples of Tetric EvoCeram (Ivoclar Vivadent, Schaan, Liechtenstein) were prepared in standardized molds and cured with a high powered LED light-curing unit, bluephase (Ivoclar Vivadent, Schaan, Liechtenstein) for 20 s. Samples were allocated to eight groups. DC of groups 1 and 2 was recorded without or after polishing. DC in groups 3 and 4 was recorded from vertically sectioned samples versus "split" samples. DC in groups 5-8 was recorded after storing samples at room temperature and humidity, in 90 +/- 2% humidity at 37 +/- 1 degrees C, distilled water at 37 +/- 1 degrees C or buffered incubation medium (BIM) at 37 +/- 1 degrees C for 24 h. Mean values of DC in polished and unpolished samples were 63.6% (+/-3.2%) and 54.7% (+/-5.2%), respectively (p < 0.0001). There was no significant difference in DC after sample-sectioning (p > 0.05). Significantly higher DC values were obtained after storing samples in BIM (76.8% +/- 2.1%) than in distilled water (59.7% +/- 5.7%), extreme humidity (60.3% +/- 3.9%) or in room conditions (63.6% +/- 3.2%) (p < 0.001). DC of an RBC measured by micro-Raman spectroscopy may be affected by differences in sample preparation and storing conditions, making it difficult to extrapolate data from in vitro studies into clinically relevant information.

摘要

本研究的目的是使用显微拉曼光谱法,测量经过不同样品制备程序和储存条件处理后的树脂基复合材料(RBC)的转化率(DC)。采用标准模具制备了90个义获嘉瓷倍健全瓷树脂(Ivoclar Vivadent,沙恩,列支敦士登)样品,并用高功率LED光固化机bluephase(Ivoclar Vivadent,沙恩,列支敦士登)固化20秒。将样品分为八组。第1组和第2组的DC在未抛光或抛光后记录。第3组和第4组的DC从垂直切片样品与“劈开”样品中记录。第5 - 8组的DC在样品于室温及湿度条件下、90±2%湿度及37±1℃、37±1℃蒸馏水或37±1℃缓冲培养液(BIM)中储存24小时后记录。抛光和未抛光样品的DC平均值分别为63.6%(±3.2%)和54.7%(±5.2%)(p < 0.0001)。样品切片后DC无显著差异(p > 0.05)。样品在BIM中储存后获得的DC值(76.8%±2.1%)显著高于在蒸馏水中(59.7%±5.7%)、极端湿度环境(60.3%±3.9%)或室温条件下(63.6%±3.2%)(p < 0.001)。通过显微拉曼光谱法测量的RBC的DC可能受样品制备和储存条件差异的影响,这使得将体外研究数据外推为临床相关信息变得困难。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验