通过背向散射积分血管内超声测量的靶病变脂质体积与择期支架植入患者术后心肌梗死之间的相关性。

The correlation between lipid volume in the target lesion, measured by integrated backscatter intravascular ultrasound, and post-procedural myocardial infarction in patients with elective stent implantation.

作者信息

Uetani Tadayuki, Amano Tetsuya, Ando Hirohiko, Yokoi Kiminobu, Arai Kosuke, Kato Masataka, Marui Nobuyuki, Nanki Michio, Matsubara Tatsuaki, Ishii Hideki, Izawa Hideo, Murohara Toyoaki

机构信息

Department of Cardiology, Chubu Rosai Hospital, 1-10-6, Komei, Minato-ku, Nagoya 465-8530, Japan.

出版信息

Eur Heart J. 2008 Jul;29(14):1714-20. doi: 10.1093/eurheartj/ehn248. Epub 2008 Jun 16.

Abstract

AIMS

The aim of this study was to perform quantitative analysis of the plaques of target lesions by integrated backscatter intravascular ultrasound (IB-IVUS) and to investigate the association between these data and the risk of post-procedural myocardial injury after stenting.

METHODS AND RESULTS

One hundred and fourteen consecutive patients who received elective stent implantations following IB-IVUS analysis were enrolled. The volume of each plaque component (lipid, fibrous, and calcified) was calculated for the target lesion. Creatine kinase-MB (CK-MB) and troponin-T (TnT) were also evaluated 18 h after procedure. We defined a post-procedural TnT level higher than three times the normal limit as a post-procedural myocardial injury. Lipid, fibrous, and calcified volumes were greater in patients with myocardial injury than in those without myocardial injury. Lipid and fibrous volumes correlated with post-procedural cardiac biomarkers, and the lipid volume fraction (lipid volume/total plaque volume) also correlated with post-procedural TnT and CK-MB. The fibrous volume fraction for plaques was found to be inversely correlated with post-procedural TnT and CK-MB. Hence, lipid volume and volume fraction were concluded to be independent predictors of post-procedural myocardial injury.

CONCLUSION

A larger plaque volume and lipid-rich plaque may be indicative of embolic events after stent implantation, resulting in myocardial injury.

摘要

目的

本研究旨在通过背向散射积分血管内超声(IB-IVUS)对靶病变斑块进行定量分析,并探讨这些数据与支架置入术后心肌损伤风险之间的关联。

方法与结果

纳入114例在IB-IVUS分析后接受择期支架植入的连续患者。计算靶病变中各斑块成分(脂质、纤维和钙化)的体积。术后18小时还评估了肌酸激酶同工酶(CK-MB)和肌钙蛋白T(TnT)。我们将术后TnT水平高于正常上限三倍定义为术后心肌损伤。发生心肌损伤的患者的脂质、纤维和钙化体积大于未发生心肌损伤的患者。脂质和纤维体积与术后心脏生物标志物相关,脂质体积分数(脂质体积/总斑块体积)也与术后TnT和CK-MB相关。发现斑块的纤维体积分数与术后TnT和CK-MB呈负相关。因此,脂质体积和体积分数被认为是术后心肌损伤的独立预测因素。

结论

较大的斑块体积和富含脂质的斑块可能提示支架植入后发生栓塞事件,导致心肌损伤。