Department of Environmental Engineering Sciences, University of Florida, Gainesville, FL 32611, USA.
J Appl Microbiol. 2008 Nov;105(5):1318-26. doi: 10.1111/j.1365-2672.2008.03855.x. Epub 2008 Jun 18.
To assess the effectiveness of iodine-treated biocidal filter media against bacterial spore aerosols.
Bacillus subtilis spores were aerosolized and introduced into a filtration system. Both treated and untreated filters exhibited high viable removal efficiency (>99.996%) with negligible variation in pressure drop during the entire experiment. The viability of collected spores on the filter was investigated by enumeration of spores extracted from the filter by vortexing. At room temperature and low relative humidity (RH), the survival fraction of the treated filter was significantly lower than that of the untreated filter (P-value < 0.05). Meanwhile, at room temperature and high RH and at high temperature and high RH, the survival fractions on the treated medium were statistically the same as the untreated control at room temperature and low RH.
Both treated and untreated filters achieved excellent viable removal efficiency for spores. The pressure drop of the treated filter was not affected by the iodine treatment. The viability of collected bacterial spores was decreased because of the exertion of iodine disinfectant.
The evaluation demonstrates that the iodine-treated filter is a viable medium for respiratory protection against infectious spore aerosols. The results warrant further evaluation of smaller biological agents, which exhibit higher penetration.
评估碘处理的杀菌过滤介质对细菌孢子气溶胶的有效性。
将枯草芽孢杆菌孢子气溶胶化并引入过滤系统。处理过和未处理过的过滤器都表现出了高的活菌去除效率(>99.996%),在整个实验过程中压力降的变化可忽略不计。通过涡旋从过滤器中提取孢子并对收集在过滤器上的孢子的活力进行计数,对收集在过滤器上的孢子的活力进行了研究。在室温低相对湿度(RH)下,处理过的过滤器的存活分数明显低于未处理的过滤器(P 值<0.05)。同时,在室温高 RH 和高温高 RH 下,处理过的介质上的存活分数与室温低 RH 下的未处理对照相同。
处理过和未处理的过滤器都实现了对孢子的极好的活菌去除效率。处理过的过滤器的压降不受碘处理的影响。收集的细菌孢子的活力由于碘消毒剂的作用而降低。
该评估表明,碘处理的过滤器是一种可行的呼吸保护介质,可防止传染性孢子气溶胶。结果证明需要进一步评估穿透性更高的较小生物制剂。