Suppr超能文献

胫骨近端锁定钢板双皮质与单皮质螺钉置入的生物力学比较:尸体模型研究

Biomechanical comparison of bicortical versus unicortical screw placement of proximal tibia locking plates: a cadaveric model.

作者信息

Dougherty Paul J, Kim Do-Gyoon, Meisterling Steve, Wybo Christopher, Yeni Yener

机构信息

Department of Orthopaedic Surgery, Henry Ford Hospital, Detroit, Michigan 48202, USA.

出版信息

J Orthop Trauma. 2008 Jul;22(6):399-403. doi: 10.1097/BOT.0b013e318178417e.

Abstract

OBJECTIVE

The purpose of this study was to compare the biomechanical properties of bicortical with unicortical screws in a proximal tibial fracture cadaveric model.

SETTING

Biomechanics laboratory at a Level 1 trauma center.

PATIENTS/PARTICIPANTS: Eight pairs (4 male and 4 female) of elderly (average age, 79 years; range, 63 to 104 years) cadaveric tibiae.

INTERVENTION

Osteotomies were performed in the proximal tibia to reproduce a 41-C2 bicondylar fracture pattern. The 4.5-mm proximal tibial periarticular locking plates (Smith-Nephew, Memphis, TN) were applied to the tibiae with 4 proximal bicortical or unicortical locking screws and 3 screws distal to the fracture site. The fixed tibiae were tested by using a materials testing machine (Instron, Canton, MA) with the axial load on the medial condyle.

OUTCOME MEASUREMENTS

The bicortical and unicortical constructs were compared for stiffness, yield load and displacement, and maximum load and displacement to failure.

RESULTS

: Bicortical screw placement significantly outperformed unicortical screw placement in stiffness (53.1 +/- 6.7 N/mm versus 35.6 +/- 7.2 N/mm, P < 0.002) and maximum load (476.5 +/- 83.8 N versus 258.9 +/- 62.1 N, P < 0.001) but the yield properties and the ultimate displacement were not significantly different.

CONCLUSION

Bicortical screw placement may provide a biomechanically superior construct than unicortical screw placement for the stabilization of unstable proximal tibia fractures.

摘要

目的

本研究旨在比较双皮质螺钉与单皮质螺钉在胫骨近端骨折尸体模型中的生物力学特性。

背景

一级创伤中心的生物力学实验室。

患者/参与者:八对(4男4女)老年(平均年龄79岁;范围63至104岁)尸体胫骨。

干预措施

在胫骨近端进行截骨术以重现41-C2双髁骨折模式。将4.5毫米胫骨近端关节周围锁定钢板(史赛克公司,田纳西州孟菲斯)应用于胫骨,使用4枚近端双皮质或单皮质锁定螺钉以及骨折部位远端的3枚螺钉。使用材料试验机(英斯特朗公司,马萨诸塞州坎顿)对内髁施加轴向载荷来测试固定好的胫骨。

观察指标

比较双皮质和单皮质结构在刚度、屈服载荷和位移、最大载荷和破坏位移方面的情况。

结果

双皮质螺钉置入在刚度(53.1±6.7N/mm对35.6±7.2N/mm,P<0.002)和最大载荷(476.5±83.8N对258.9±62.1N,P<0.001)方面明显优于单皮质螺钉置入,但屈服特性和最终位移无显著差异。

结论

对于不稳定的胫骨近端骨折的固定,双皮质螺钉置入可能比单皮质螺钉置入提供生物力学性能更优的结构。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验