Suppr超能文献

不同粘接剂对Procera Allceram氧化铝全瓷冠内冠边缘适合性的影响——一项实验研究。

Influence of different luting agents on the marginal discrepancy of Procera Allceram alumina crown copings--an experimental study.

作者信息

Pilathadka Shriharsha, Slezák Radovan, Vahaloá Dagmar, Kudiyirickal Marina George, Sukumar Sujith

机构信息

Department of Prosthodontics, Charles University in Prague, Faculty of Medicine, University Hospital in Hradec Králové, Czech Republic.

出版信息

Acta Medica (Hradec Kralove). 2008;51(1):13-8. doi: 10.14712/18059694.2017.2.

Abstract

Two maxillary first molars and two central incisor typhodont teeth were prepared with 0.8 mm chamfer, 2.0 mm occlusal reduction, and 6 degree taper. The prepared teeth were duplicated 9 times to obtain 36 die stone models and divided into three groups (n = 12). Luting agents tested were zinc phosphate, glass ionomer and resin cement. Procera AllCeram 0.6 mm coping was fixed with a calibrated finger force of 50 N. The absolute marginal discrepancy was measured using the scanning electron microscope on four axial walls with 4 measurements on each wall to obtain a total of 16 readings for one tooth. Mann Whitney U test was applied to find significant differences between luting cements and Kruskal Wallis tests among groups. Results The absolute marginal discrepancies of cements were in reducing order zinc phosphate (AZ) 53 microm; resin (AR) 44.5 microm, glass ionomer (AG) 29 microm. There was a significant difference among luting cements AG V/s AZ (p = 0.001) and AR V/s AG (p = 0.003), except AR V/s AZ (p = 0.213). All axial surfaces except mesial showed a significant difference. Conclusion The study concluded that different luting media have a definite effect over the final fit of AllCeram coping. Absolute marginal discrepancy was within the accepted level of 100 microm. Distal axial surface demonstrated a wider gap among all the luting agents.

摘要

选取两颗上颌第一磨牙和两颗中切牙的仿真牙,制备出具有0.8毫米倒角、2.0毫米咬合面磨除量和6度锥度的牙体。将制备好的牙齿复制9次,得到36个石膏模型,并分为三组(n = 12)。所测试的粘结剂为磷酸锌、玻璃离子水门汀和树脂水门汀。使用校准后的手指力量50牛固定Procera全瓷0.6毫米全冠。使用扫描电子显微镜在四个轴壁上进行测量,每个壁测量4次,以获得一颗牙齿总共16个读数,从而测量绝对边缘差异。应用曼-惠特尼U检验来发现粘结水门汀之间的显著差异,并应用克鲁斯卡尔-沃利斯检验来比较各组之间的差异。结果 水门汀的绝对边缘差异从大到小依次为:磷酸锌(AZ)53微米;树脂(AR)44.5微米,玻璃离子水门汀(AG)29微米。粘结水门汀之间存在显著差异,AG与AZ相比(p = 0.001),AR与AG相比(p = 0.003),但AR与AZ相比除外(p = 0.213)。除近中面外,所有轴面均显示出显著差异。结论 该研究得出结论,不同的粘结介质对全瓷全冠的最终贴合度有一定影响。绝对边缘差异在可接受的100微米范围内。远中轴面在所有粘结剂之间显示出较宽的间隙。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验