Suppr超能文献

钙化是图像引导放射治疗中前列腺定位的潜在替代指标。

Calcifications are potential surrogates for prostate localization in image-guided radiotherapy.

作者信息

Zeng Grace G, McGowan Tom S, Larsen Tessa M, Bruce Lisa M, Moran Natasha K, Tsao Jonathan R, MacPherson Miller S

机构信息

Carlo Fidani Peel Cancer Center, the Credit Valley Hospital, Mississauga, ON, Canada.

出版信息

Int J Radiat Oncol Biol Phys. 2008 Nov 15;72(4):963-6. doi: 10.1016/j.ijrobp.2008.07.021.

Abstract

PURPOSE

To investigate the feasibility of using calcifications as surrogates for the prostate position during cone-beam computed tomography (CBCT) image-guided radiotherapy.

METHODS AND MATERIALS

The twice-weekly CBCT images taken during the treatment course of 4 patients were retrospectively studied for the stability of the calcifications. The geometric center of three fiducial markers was used as the reference. The planning CT images of 131 prostate patients recently treated with external beam radiotherapy at our center were reviewed to estimate the calcification occurrence rate. Analysis was conducted using the Varian Eclipse treatment planning system. Two patients were treated using prostate calcifications as the landmark in on-line registration. Both the Varian standard and the low-dose CBCT modes were used for imaging.

RESULTS

The calcifications were found to be stable during the treatment course. At the 95% confidence interval, the difference between the distance from an identified calcification to the fiducial markers on CBCT and the distance on the planning CT scans was 0.2 +/- 2.0 mm, 0.8 +/- 2.2 mm, and 0.4 +/- 2.4 mm in the left-right, anteroposterior, and superoinferior direction, respectively. Of the 131 patients, 46 (35%) had well-defined calcifications either inside the prostate or near the borders. Our experience in treating the first 2 patients demonstrated that the calcifications are easily distinguished on low-dose scans and that calcification registration can be precisely performed.

CONCLUSION

The results of our study have shown that calcifications can be reliable markers of prostate position and allow for precise image guidance with a low-imaging dose. With this approach, potentially about one-third of prostate patients could benefit from precise image guidance without the invasive use of markers.

摘要

目的

探讨在锥形束计算机断层扫描(CBCT)图像引导放射治疗期间,使用钙化作为前列腺位置替代物的可行性。

方法与材料

回顾性研究4例患者治疗过程中每周两次的CBCT图像,观察钙化的稳定性。使用三个基准标记的几何中心作为参考。回顾了我院近期接受外照射放疗的131例前列腺癌患者的计划CT图像,以评估钙化发生率。使用瓦里安Eclipse治疗计划系统进行分析。2例患者在在线配准中使用前列腺钙化作为标记。使用瓦里安标准模式和低剂量CBCT模式进行成像。

结果

发现钙化在治疗过程中是稳定的。在95%置信区间,CBCT上识别出的钙化到基准标记的距离与计划CT扫描上的距离在左右、前后和上下方向的差异分别为0.2±2.0 mm、0.8±2.2 mm和0.4±2.4 mm。131例患者中,46例(35%)在前列腺内部或边界附近有明确的钙化。我们治疗前2例患者的经验表明,钙化在低剂量扫描中很容易区分,并且可以精确地进行钙化配准。

结论

我们的研究结果表明,钙化可以作为前列腺位置的可靠标记,并允许在低成像剂量下进行精确的图像引导。通过这种方法,大约三分之一的前列腺癌患者可能受益于精确的图像引导,而无需侵入性地使用标记物。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验