Park Chang Hyun, Lee Sung Jin
Department of Ophthalmology, Soonchunhyang University Hospital, Seoul, Korea.
Korean J Ophthalmol. 2008 Dec;22(4):205-9. doi: 10.3341/kjo.2008.22.4.205.
We describe a suture fixation technique for a single-piece foldable acrylic closed-loop intraocular lens (IOL) (C-flex, Rayner).
In our experimental model analyzing the stability of acrylic haptics, we confirmed that the IOL could be in counterpoise without tilt using only a two-point fixation. This new surgical technique was performed in seven patients.
The unique haptic design allows easy and secure suture fixation. The clinical outcomes were encouraging.
It is conceivable that better stabilization can be achieved by the broad arc of distal haptic-tissue contact, in addition to suture fixation, using our surgical technique with the C-flex IOL.